Registration Dossier

Environmental fate & pathways

Biodegradation in water: screening tests

Administrative data

Endpoint:
biodegradation in water: ready biodegradability
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: GLP study according to EU/OECD guideline

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
1995

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
EU Method C.4-C (Determination of the "Ready" Biodegradability - Carbon Dioxide Evolution Test)
GLP compliance:
yes

Test material

Reference
Name:
Unnamed
Type:
Constituent

Study design

Inoculum or test system:
sewage, domestic (adaptation not specified)

Results and discussion

% Degradation
Parameter:
% degradation (CO2 evolution)
Value:
0
Sampling time:
28 d

Applicant's summary and conclusion

Interpretation of results:
under test conditions no biodegradation observed