Description of key information

at 60°C = 9225 mPa s (dynamic)
at 75°C = 11800 mPa s (dynamic)

Key value for chemical safety assessment

Additional information

The physical state of the substance prevented from executing the study at the temperatures of 20°C and 40°C. At these temperatures, the substance is pushed towards the walls (using a coaxial-cylinder viscometer) and the spindle is free to rotate. The minimun temperature at which the measurement was possible was found to be 60°C.

The results at 60°C and 75°C measured according to OECD 114 are above reported.