Registration Dossier

Physical & Chemical properties

Vapour pressure

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
vapour pressure
Data waiving:
study scientifically not necessary / other information available
Justification for data waiving:
the study does not need to be conducted because the melting point is above 300°C
Reason / purpose for cross-reference:
data waiving: supporting information

Description of key information

Based on high melting point, the substance dialuminium chloride pentahydroxide is anticipated to have very low vapour pressure at ambient temperature.

Key value for chemical safety assessment

Vapour pressure:
0.001 Pa
at the temperature of:
20 °C

Additional information

No experimental study is deemed necessary: based on the properties of the substance (solid with mp >300°C) the vapour pressure is expected to be very low, and likely below the measurable range (< 10E-10 Pa).

However, a key value is required for purpose of CSA. As no realistic value can be provided, an arbitrary value of 0.001 Pa is proposed, in order to lie below the lower threshold of 0.01 Pa used by the risk assessment model.