Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
test procedure in accordance with national standard methods with acceptable restrictions
Remarks:
Performed according to relevant guideline, however not compliant with GLP
Qualifier:
according to guideline
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
Version / remarks:
2002
Qualifier:
according to guideline
Guideline:
ISO No., other: ASTM D93-07
GLP compliance:
no
Remarks:
The study was performed compliant with a quality management system according to DIN EN ISO 9001 : 2008 and DIN EN ISO 14001 : 2005.
Type of method:
closed cup
Remarks:
MP EN22719A/ ISO2719A
Flash point:
122 °C
Atm. press.:
1 013 hPa
Remarks on result:
other: Arithmetic mean value of 2 replicate determinations

Results of single measurements:

1) determination: 124 °C

2) determination: 120 °C

Flash point (arithmetic mean value): 122 °C

Atmospheric pressure correction to 1013 hPa was automatically performed by the measurement device.

Conclusions:
Flash point = 122 °C at 1013 hPa
Executive summary:

The flashpoint was determined according to the Pensky-Martens closed cup method (non-equilibirum method; DIN EN ISO 2719 / ASTM D93-07). The laboratory complied with a quality management system according to DIN EN ISO 9001 : 2008 and DIN EN ISO 14001 : 2005. Based on replicate measurements, the following result was determined:

Flash point: (1013 hPa) 122 °C

Description of key information

Flash point: (1013 hPa) 122 °C

Key value for chemical safety assessment

Flash point at 101 325 Pa:
122 °C

Additional information

For the test item, the flash point was determined according to EN ISO 2719 (Pensky-Martens closed cup method) to be 122 °C

(1013 hPa). In conclusion, the test item has not to be classified as flammable liquid according to REGULATION (EC) 1272/2008 (CLP) Annex 1: 2.6.