Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Administrative data

Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: No GLP study but other quality assurance

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2010

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
OECD Guideline 110 (Particle Size Distribution / Fibre Length and Diameter Distributions)
Principles of method if other than guideline:
The particle size of the samples is determined by sieving.
GLP compliance:
no
Type of method:
sieving
Type of distribution:
counted distribution

Test material

Constituent 1
Reference substance name:
Matte, copper
EC Number:
266-967-8
EC Name:
Matte, copper
Cas Number:
67711-91-5
IUPAC Name:
matte, copper
Details on test material:
Sample collection made according to ECI/REACH Copper Consortium Standards Protocols (see IUCLID section 1.4 and 4.1 attachment)
Sample description Sample Code Lab Code
B2 Matte, Flash furnace type (composite from grinded material) AC_B2_625559 09TT02788
B2 Matte, Electric furnace type (composite from grinded material) AC_B2_625208 09TT02787
B2 matte, blast furnace type (composite from grinded material) KGHM_B2 10TT00139
B2 matte, white matte-type (site 2C importer) (representative) El Teniente 09TT07029
B2 matte, white matte-type (site 2D importer) Codelco Norte 09TT07719

Results and discussion

Particle sizeopen allclose all
Percentile:
D50
Remarks on result:
other: Migrated from fields under 'Mass median diameter' as D50 percentile. No source field for Standard deviation.
Percentile:
D50
Mean:
> 5 000 µm
Remarks on result:
other: sample 09TT02787
Percentile:
D50
Mean:
4 317 µm
Remarks on result:
other: sample 09TT02788
Percentile:
D50
Mean:
1 156 µm
Remarks on result:
other: sample 09TT07719
Percentile:
D50
Mean:
832 µm
Remarks on result:
other: sample 09TT00139

Any other information on results incl. tables

Table 4: Particle size distribution

Sample

 

09TT02787

 

09TT02788

 

09TT07029

 

09TT07719

 

10TT00139

 

Size

 

Retained

 

Retained

 

Retained

 

Retained

 

Retained

 

mesh

 mm

g

%

g

%

g

%

g

%

g

%

 

5.000

63.81

50.35

60.37

35.93

0.00

 

 

 

 

 

6

3.360

42.55

33.58

52.60

31.31

30.68

11.76

6.66

2.81

4.64

3.62

8

2.380

5.83

4.60

46.42

27.63

40.88

15.67

24.23

10.22

12.55

9.78

16

1.190

5.26

4.15

6.81

4.05

61.58

23.61

85.15

35.92

32.87

25.62

20

0.841

0.08

0.06

0.42

0.25

24.18

9.27

26.76

11.29

13.66

10.65

30

0.595

9.20

7.26

1.38

0.82

22.90

8.78

24.27

10.24

12.61

9.83

40

0.420

 

 

 

 

20.00

7.67

16.39

6.91

10.99

8.57

50

0.297

 

 

 

 

14.37

5.51

14.51

6.12

8.41

6.55

140

0.106

 

 

 

 

29.08

11.15

26.13

11.02

17.14

13.36

200

0.075

 

 

 

 

4.90

1.88

4.61

1.94

3.45

2.69

325

0.045

 

 

 

 

5.41

2.07

4.54

1.92

4.04

3.15

 

0.020

 

 

 

 

3.91

1.50

2.64

1.11

2.96

2.31

 

-0.020

 

 

 

 

2.97

1.14

1.16

0.49

4.98

3.88

Sum

 

126.73

100.00

168.00

100.00

260.86

100.00

237.05

100.00

128.3

100

Sample

Matte

Matte

White metal

White metal

Matte

Sample

B2

B2

B2

B2

B2

Outotec code

09TT02787

09TT02788

09TT07029

09TT07719

10TT00139

D80, µm

>5000

>5000

2827

2135

2035

D50, µm

>5000

4317

1235

1156

832

Applicant's summary and conclusion

Conclusions:
UVCB is a massive (at Room temperature), that showed in WC (samples grinded prior testing) less than 4% particles below 20µm, and typically D50 above 800 µm. Results can be used to support classification.
Executive summary:

Substance is a massive solid at RT (see picture in IUCLID section 1.4 "sampling protocol") which particle size distribution (IUCLID section 4.5) for a WC sample (ie samples crushed and grinded prior to testing) showed D50 > or equal 832 µm, with particles < 20 µm less than 4% (WC). Routes for exposure to consider is therefore only oral (ie inhalation excluded).