Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Toxicological information

Basic toxicokinetics

Currently viewing:

Administrative data

Endpoint:
basic toxicokinetics in vitro / ex vivo
Type of information:
experimental study
Adequacy of study:
weight of evidence
Study period:
03.05.2018 – 26.06.2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
test procedure in accordance with generally accepted scientific standards and described in sufficient detail
Cross-referenceopen allclose all
Reason / purpose for cross-reference:
assessment report
Reason / purpose for cross-reference:
read-across: supporting information

Data source

Materials and methods

Objective of study:
metabolism
Principles of method if other than guideline:
Hydrolysis of benzoic acid esters was determined and evaluated as described in the EFSA guidelines “Note for Guidance for Food Contact Materials.”
GLP compliance:
no

Test material

Constituent 1
Reference substance name:
Benzoic acid isononylester
Cas Number:
670241-72-2
IUPAC Name:
Benzoic acid isononylester
Details on test material:
Labelled : Isononylbenzoat
Batch Number : 04/3945-3947
Retest date : 12 July 2005
Received from : Oxeno GmbH
Date received : 21 February 2005
Amount received : Approximately 2 kg
Description : Clear liquid
Storage at RTC : Room temperature
RTC reference number : 9428

Results and discussion

Any other information on results incl. tables

Purity

Sample 1 shows benzoic acid esters, the derivatization showed no by-products like alcohols or acids.

Hydrolysis with gastric-fluid simulant

The hydrolysis rates in acidic medium after 2 hours for the benzoic acid esters are 30-40%. The degradation rate of the sum of all isomers of the benzoic acid esters is about 35%.

Hydrolysis with intestinal-fluid simulant

In low alkaline-enzyme medium all detected esters in sample 1 indicates a continuously degradation. The hydrolysis rates after 4 hours for the benzoic acid esters are 50-70%. The degradation rate of the sum of all isomers of the benzoic acid esters is about 62%.

Mass balance

Because of the not identified structures of almost all esters present in the solution there is no possibility for the calculation of the mass balance.

 Ester  Hydrolysis rate of ester

 Benzoic acid ester 1

 69

 Benzoic acid ester 2

 76

 Benzoic acid ester 3  80
 Benzoic acid ester 4  81
 Sum of benzoic acid esters  76

Applicant's summary and conclusion