Registration Dossier

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2 March 2012
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Guideline study (ASTM D 3278-96)
Qualifier:
according to guideline
Guideline:
ISO No., other: ASTM D 3278-96
GLP compliance:
no
Type of method:
equilibrium method closed cup
Flash point:
70 °C
Atm. press.:
101.5 kPa
Remarks on result:
other: Flash observed.
Conclusions:
The flash point of the test item is 70 °C.
Executive summary:

The flash point of the test item was determined according to ASTM D 3278-96 (2011) by the equilibrium closed cup method. The flash point of the test item is 70 °C (flash observed).

Description of key information

The flash point of the test item is 70 °C at 101.5 kPa.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
70 °C

Additional information