Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 231-494-8 | CAS number: 7585-41-3
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Biodegradation in water and sediment: simulation tests
Administrative data
- Endpoint:
- biodegradation in water: sediment simulation testing
- Data waiving:
- study scientifically not necessary / other information available
- Justification for data waiving:
- other:
- Justification for type of information:
- JUSTIFICATION FOR DATA WAIVING
see attached justification
Cross-referenceopen allclose all
- Reason / purpose for cross-reference:
- data waiving: supporting information
Reference
- Endpoint:
- biodegradation in water: ready biodegradability
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Reliability:
- 2 (reliable with restrictions)
- Rationale for reliability incl. deficiencies:
- guideline study with acceptable restrictions
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 301 C (Ready Biodegradability: Modified MITI Test (I))
- GLP compliance:
- no
- Specific details on test material used for the study:
- - Name of test material (as cited in study report): D & C Red No. 7
- Oxygen conditions:
- aerobic
- Inoculum or test system:
- mixture of sewage, soil and natural water
- Details on inoculum:
- - Source of inoculum/activated sludge: in March, June, September, and December, sludge was sampled at the following 10 places in Japan:
1. Fukogawa city sewage plant
2. Fukashiba industry sewage plant
3. Nakahama city sewage plant
4. Ochiai city sewage plant
5. Kitakami river
6. Shinano river
7. Yoshino river
8. Lake Biwa
9. Hiroshima bay
10. Dookai bay; sampling:
1. City sewage: returned sludge from sewage plants was taken.
2. Rivers, lake and sea: surface water and surface soil which were in contact with atmosphere were collected.
- Method of cultivation: about 30 minutes after ceasing aeration to the sludge mixture, supernatant corresponding to about 1/3 of the whole volume was removed. Then the equal volume of dechlorinated water was added to the remaining portion and aerated again, followed by addition of synthetic sewage at a concentration of 0.1% (w/v). This procedure was repeated once every day. The culturing was carried out at 25 ± 2 °C. 5 L of the filtrate of the supernatant of old activated sludge was mixed with 500 mL of the filtrate of the supernatant of new sludge and cultured at pH 7.0 ± 1.0 under sufficient aeration using prefiltered open air. During the cultivation, appearance of the supernatant, precipitability, formation of flock, pH, dissolved oxygen concentration in the solution and temperature were checked and necessary adjustments were made, Microflora in the activated sludge was microscopically observed and sludge with no abnormal symptom was used for the test.
- Concentration of sludge: 30 mg/L - Duration of test (contact time):
- 28 d
- Initial conc.:
- 100 mg/L
- Based on:
- test mat.
- Parameter followed for biodegradation estimation:
- O2 consumption
- Details on study design:
- TEST CONDITIONS
- Composition of medium: 3 mL each of four stock solutions, as described in JIS K 0102-1986-21, are diluted to 1000 mL with purified water
- pH: 7.0
- pH adjusted: yes
- Suspended solids concentration: determined according to Method Japanese Industrial Standards (JIS) K 0102-1986-14.1
TEST SYSTEM
- Culturing apparatus: Closed system oxygen consumption measuring apparatus (Coulometer: Ohkura Electric Co., Ltd.); 300 mL vessel, absorbent for evolving carbon dioxide Soda lime No .l (extra pure reagent, Wako Pure Chemical Industries, Ltd.).
- Number of culture flasks/concentration: 1
- Measuring equipment: Coulometer, Okhura Electric Co., Ltd.
- Test performed in open system: no
- Details of trap for CO2 and volatile organics if used: soda lime, extra pure, Wako Pure Chemical Industries, Ltd.)
CONTROL AND BLANK SYSTEM
- Inoculum blank: yes
- Abiotic sterile control: yes
- Toxicity control: no - Reference substance:
- aniline
- Key result
- Parameter:
- % degradation (O2 consumption)
- Value:
- >= 9 - <= 12
- Sampling time:
- 28 d
- Interpretation of results:
- not readily biodegradable
- Reason / purpose for cross-reference:
- data waiving: supporting information
Reference
- Endpoint:
- biodegradation in water: ready biodegradability
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- guideline study
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 301 B (Ready Biodegradability: CO2 Evolution Test)
- GLP compliance:
- yes
- Specific details on test material used for the study:
- - Storage condition of test material: At room temperature at about 20 °C, away from direct sunlight
- Oxygen conditions:
- aerobic
- Inoculum or test system:
- activated sludge, domestic, non-adapted
- Details on inoculum:
- - Source of inoculum/activated sludge: aerobic activated sludge from a wastewater treatment treating predominantly domestic wastewater
- Preparation of inoculum for exposure: Sludge was washed twice with tap water by centrifugation and the supernatant liquid phase was decanted. A homogenized aliquot of the final sludge suspension was weighed, thereafter dried and the ratio of wet to dry weight was calculated. Based on this ratio, calculated amounts of wet sludge were suspended in test water to obtain a concentration equivalent to 4 g (±10%) dry material per liter. During the holding period of one day prior to use, the sludge was aerated at room temperature. Prior to use, the sludge was diluted with test water to a concentration of about 1 g dry material per liter. Defined volumes of this diluted activated sludge were added to test water to obtain a final concentration of 30 mg dry material per liter. - Duration of test (contact time):
- 28 d
- Initial conc.:
- 33 mg/L
- Based on:
- test mat.
- Initial conc.:
- 15.3 mg/L
- Based on:
- TOC
- Parameter followed for biodegradation estimation:
- CO2 evolution
- Details on study design:
- TEST CONDITIONS
- Composition of medium: One day before test start (Day-1), between 2400 and 3000 mL of untreated test medium was filled into the flasks and 90 ml activated sludge inoculum was added. Then aeration overnight with C02-free air on the following day (Day 0), defined amounts of the test item were directly added to the test flasks and made up to a volume of 3 L with test water.
- Solubilising agent: none
- Test temperature: 21-23 °C
- pH: 7.2 - 7.4
- Continuous darkness: yes
TEST SYSTEM
- Culturing apparatus: 5-liter all-glass amber bottles
- Number of culture flasks/concentration: 2
- Method used to create aerobic conditions: air was led through a bottle containing about 750 mL of a 2 M NaOH solution to trap CO2. The CO2-free air was passed through the test solutions at a rate corresponding to about 30-100 mL/min.
- Details of trap for CO2 and volatile organics: two absorber flasks, the first one containing 300 mL 0.05 M NaOH and the second one containing 200 mL 0.05 M NaOH, were connected in series to the exit air line of each test flask.
SAMPLING
- Sampling frequency test item and inoculum control: day 2, 5, 7, 9, 12, 14, 19, 23, 27, 28, 29
- Sampling frequency procedure control: day 2, 7, 14, 28, 29
- Sampling frequency toxicity control: day 7, 14, 28, 29
- Sampling method: aliquot of 5.0 mL withdrawn from the absorber flask nearest to the test flask for analysis of inorganic carbon
CONTROL AND BLANK SYSTEM
- Inoculum blank: 2 replicates
- Toxicity control: 1 replicate
- Procedure control: 2 replicates - Reference substance:
- benzoic acid, sodium salt
- Key result
- Parameter:
- % degradation (CO2 evolution)
- Value:
- 0
- Sampling time:
- 28 d
- Results with reference substance:
- Mean degradation rate after 28 days = 77.1%
- Validity criteria fulfilled:
- yes
- Interpretation of results:
- under test conditions no biodegradation observed
- Reason / purpose for cross-reference:
- data waiving: supporting information
Reference
- Endpoint:
- biodegradation in water: ready biodegradability
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- guideline study
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 301 C (Ready Biodegradability: Modified MITI Test (I))
- GLP compliance:
- yes
- Oxygen conditions:
- aerobic
- Inoculum or test system:
- mixture of sewage, soil and natural water
- Details on inoculum:
- - Source of inoculum/activated sludge: sampled at 10 locations in Japan
- Concentration of sludge: 30 mg/L - Duration of test (contact time):
- 28 d
- Initial conc.:
- 100 mg/L
- Based on:
- test mat.
- Parameter followed for biodegradation estimation:
- O2 consumption
- Details on study design:
- TEST CONDITIONS
- Test temperature: 25 ± 1 °C
TEST SYSTEM
- Culturing apparatus: Asahi Techneion Co., Ltd.
- Number of culture flasks/concentration: 3
CONTROL AND BLANK SYSTEM
- Inoculum blank: yes
- Toxicity control: yes - Reference substance:
- aniline
- Key result
- Parameter:
- % degradation (O2 consumption)
- Value:
- 0
- Sampling time:
- 28 d
- Validity criteria fulfilled:
- yes
- Interpretation of results:
- under test conditions no biodegradation observed
- Reason / purpose for cross-reference:
- data waiving: supporting information
Reference
- Endpoint:
- water solubility
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- 2008
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- comparable to guideline study
- Qualifier:
- equivalent or similar to guideline
- Guideline:
- OECD Guideline 105 (Water Solubility)
- Version / remarks:
- and ETAD method
- Principles of method if other than guideline:
- To measure the partition coefficient of pigments utilising the standard OECD Guideline 107 is extremely difficult because of the problems associated with the inherent very low solubilities. The following procedure is used for determining the LogPow of low solubility substances and in particular that of pigments.
The partition coefficient was estimated based on the ratio of the solubilities in n-octanol and in water. The individual solubilities were determined by flask method based on OECD Guideline 105 and the ETAD method.
A defined amount of the pigment (see table 1) was transferred to a 100 ml flask with glass stopper and 60 ml of water (deionised, 18.2 MOcm). This was stirred at 70°C for 2 hours, and then 72 hours in an air conditioned laboratory (T = 23°C). The suspension was then centrifuged (10 000 rpm, 10 min) and filtered once through a standard paper filter, twice through a 0.2 μm membrane filter (Millipore) and twice through a 0.025μm membrane filter (Millipore). If particles were detected in the solution
(turbidity), the final filtration step was repeated until a perfectly clear solution was acheived.
The above procedure was conducted in parallel for a total of 2 water (deionised, 18.2 MOcm) samples and of 2 n-octanol (Sigma-Aldrich, spectrophotometric grade) samples. - GLP compliance:
- no
- Type of method:
- flask method
- Specific details on test material used for the study:
- - Name of test material (as cited in study report): PIGMENT RED 48:1, PIGMENT RED 48:1, lab sample (non-resin coated), TK 10318
- Analytical purity: 94.3% w/w
- Substance type: Organic
- Physical state: Solid (powder)
- Lot/batch No.: DMG6708
- Expiration date of the lot/batch: January 01st, 2017 - Key result
- Water solubility:
- < 25 µg/L
- Conc. based on:
- test mat. (total fraction)
- Incubation duration:
- 72 h
- Temp.:
- 23 °C
- Remarks on result:
- other: The pH was not reported.
- Conclusions:
- The water solubility of test substance was determined to be <25 µg/L at 23°C.
- Reason / purpose for cross-reference:
- data waiving: supporting information
Reference
- Endpoint:
- partition coefficient
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- 2008
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- comparable to guideline study
- Qualifier:
- equivalent or similar to guideline
- Guideline:
- other: OECD Guideline 105 and ETAD method
- Principles of method if other than guideline:
- To measure the partition coefficient of pigments utilising the standard OECD Guideline 107 is extremely difficult because of the problems associated with the inherent very low solubilities. The following procedure is used for determining the LogPow of low solubility substances and in particular that of pigments.
The partition coefficient was estimated based on the ratio of the solubilities in n-octanol and in water. The individual solubilities were determined by flask method based on OECD Guideline 105 and the ETAD method.
A defined amount of the pigment (see table 1) was transferred to a 100 ml flask with glass stopper and 60 ml of water (deionised, 18.2 MOcm). This was stirred at 70°C for 2 hours, and then 72 hours in an air conditioned laboratory (T = 23°C). The suspension was then centrifuged (10 000 rpm, 10 min) and filtered once through a standard paper filter, twice through a 0.2 μm membrane filter (Millipore) and twice through a 0.025μm membrane filter (Millipore). If particles were detected in the solution (turbidity), the final filtration step was repeated until a perfectly clear solution was acheived.
The above procedure was conducted in parallel for a total of 2 water (deionised, 18.2 MOcm) samples and of 2 n-octanol (Sigma-Aldrich, spectrophotometric grade) samples. - GLP compliance:
- no
- Type of method:
- shake-flask method to: flask method
- Partition coefficient type:
- octanol-water
- Specific details on test material used for the study:
- - Name of test material (as cited in study report): PIGMENT RED 48:1, PIGMENT RED 48:1, lab sample (non-resin coated), TK 10318
- Analytical purity: 94.3% w/w
- Substance type: Organic
- Physical state: Solid (powder)
- Lot/batch No.: DMG6708
- Expiration date of the lot/batch: January 01st, 2017 - Analytical method:
- high-performance liquid chromatography
- other: UV/Vis
- Key result
- Type:
- log Pow
- Partition coefficient:
- > 0.11
- Temp.:
- 23 °C
- Remarks on result:
- other: The pH was not reported.
- Details on results:
- Solubility in n-octanol: 31-33 µg/L UV/Vis)
Solubility in water: < 25 µg/L (HPLC-DAD)
Weight in n-octanol/water: 54.2-56.8 mg/100mL - Conclusions:
- The partition coefficient of test substance was estimated to be log Pow= >0.11 at 23°C.
- Reason / purpose for cross-reference:
- data waiving: supporting information
Reference
- Endpoint:
- additional information on environmental fate and behaviour
- Remarks:
- Dispersion stability in simulated environmental media
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- 2020
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- guideline study
- Qualifier:
- according to guideline
- Guideline:
- other: OECD 318
- GLP compliance:
- yes (incl. QA statement)
- Executive summary:
The dispersion stability of Pigment Red 48:1 depends especially on pH and water hardness. In 0 mM Ca at pH 7 and 9 the stability was high. At pH 4 in 0 mM Ca and at pH 9 in 1 mM Ca the stability was intermediate. The stability at all other conditions was low
At any of the time points mentioned in the TG-318, the influence of Ca is critical. Regardless of pH, the pigment is categorized at the 24h-sampling time as “unstable” in 10 mM Ca, representing high water hardness.
After 6h, the samples showed high dispersion stability in 0 mM Ca and at pH 9 in 1 mM Ca. Stability at all other conditions was either intermediate (pH 4 and 7 in 1 mM Ca) or low (all samples in 10 mM Ca).
After 24 hoursthe stability for samplesin 0 mM Ca at pH 7 and 9 was high. For the samples at pH 4 in 0 mM Ca and at pH 9 in 1 mM Ca the stability was intermediate. The stability at all other conditions was low.
Table 1: Full results of the dispersion stability in the presence of NOM
Ca(NO3)2 |
Stability after 6h |
Standard deviation |
Stability after 15h |
Standard deviation |
Stability after 24h |
Standard deviation |
|
[mM] |
[%] |
[%] |
[%] |
[%] |
[%] |
[%] |
|
|
|
|
|
||||
pH 4 |
0 |
98.8 |
0.4 |
94.7 |
1.5 |
86.6 |
2.9 |
pH 4 |
1 |
34.6 |
6.9 |
12.5 |
3.9 |
7.7 |
2.0 |
pH 4 |
10 |
6.5 |
1.2 |
3.5 |
0.2 |
2.8 |
0.3 |
. |
|
|
|
|
|
|
|
pH 7 |
0 |
99.7 |
0.2 |
97.7 |
0.7 |
95.8 |
1.6 |
pH 7 |
1 |
17.9 |
1.2 |
5.8 |
0.5 |
3.0 |
0.2 |
pH 7 |
10 |
5.6 |
0.4 |
2.0 |
0.4 |
1.2 |
0.4 |
. |
|
|
|
|
|
|
|
pH 9 |
0 |
99.9 |
0.8 |
99.2 |
1.1 |
97.9 |
0.3 |
pH 9 |
1 |
100.0 |
0.1 |
65.1 |
8.5 |
46.4 |
4.9 |
pH 9 |
10 |
5.2 |
0.1 |
2.2 |
0.0 |
1.6 |
0.0 |
To rationalize the observed dispersion stability, we finally checked the particle size distribution directly in the environmental medium (exact same sample preparation as for the UV/VIS measurements). We applied the NanoDefine method of Analytical Ultracentrifugation (SOP AUC-RI). The centrifugation parameters are given in the methods section.
The observed size distributions confirm the moderate agglomeration at 1 mM Ca, pH7, with NOM. If the particles would have been significantly dissolved, no size distribution would be observable at all by this method, which relies on the detection of the movement of particles during centrifugal separation.
Additionally, the centrifugation methods include a determination of the remaining absorption after centrifugation, fully consistent with the conventional determination of the dissolved fraction after centrifugation as recommended by the TG-318. The remaining absorption was measured at c.a 0.031.This is a fraction of 2.1% of the initial absorption, but actually is close to the LOD of the built-in UV/Vis detector. Considering the LOD, between 0% and 2.1% of the sample may have been dissolved.
All evidence combined, the results after centrifugation confirm that at least 97.9% of the observed dispersion stability has to be attributed to the particles, not to dissolution.
Data source
Materials and methods
Results and discussion
- Transformation products:
- no
- Remarks:
- not expected according to substance properties
Applicant's summary and conclusion
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.