Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Environmental fate & pathways

Adsorption / desorption

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
adsorption / desorption: screening
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2008
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Guideline study completed under GLP
Qualifier:
according to guideline
Guideline:
OECD Guideline 121 (Estimation of the Adsorption Coefficient (Koc) on Soil and on Sewage Sludge using High Performance Liquid Chromatography (HPLC))
Deviations:
not specified
Qualifier:
according to guideline
Guideline:
EU Method C.19 (Estimation of the Adsorption Coefficient (KOC) on Soil and Sewage Sludge Using High Performance Liquid Chromatography (HPLC))
Deviations:
not specified
GLP compliance:
yes (incl. QA statement)
Type of method:
HPLC estimation method
Media:
soil/sewage sludge
Test temperature:
35 +- 1°C
Details on study design: HPLC method:
Instrument: Alliance Separation Module 2695 (Waters, Milford, MA, USA) Detector: Dual lambda Absorbance Detector 2487 (Waters) Column: 150 mm x 4.6 mm id. Hypersil BDS-CN; dp = 5 microm (Thermo, San Jose, CA, USA) Column temperature: 35 +- 1 °C Mobile phase neutral pH: 30/70 (v/v) methanol/water Flow: 1 ml/min Injection volume: 10 microL UV detection: 210 nm
Analytical monitoring:
yes
Type:
Koc
Value:
< 20.9 dimensionless
Temp.:
35 °C
Type:
log Koc
Value:
< 1.32 dimensionless
Temp.:
35 °C
Validity criteria fulfilled:
not specified
Conclusions:
log Koc of the test substance was < 1.32 (Koc < 20.9)
Executive summary:

The log Koc of MPKO was determined by means of HPLC. In the chromatogram of the test solution, one test substance peak was observed at a retention time of 2.6 minutes. Under the same analytical conditions, the retention time of phenol (log Koc = 1.32) was 3.1 minutes. Hence, it was concluded that the log Koc of the test substance was < 1.32 (Koc < 20.9)

Description of key information

Key value for chemical safety assessment

Koc at 20 °C:
20.9

Additional information

One study investigating the adsorption of 2-Pentanone oxime was available. The adsorption coefficient was determined in a GLP-study according to OECD guideline 121 using HPLC. The determined log Koc was < 1.32 (KOC: < 20.9).