Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2007-11-07 - 2008-05-30
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Remarks:
Non GLP.
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Version / remarks:
Directive 92/69/EEC, Official Journal L 383 A 1992, Pensky-Martens method, ASTM D93
GLP compliance:
no
Remarks:
Study performed and documented equivalent to GLP standards
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus
Dynamic viscosity of test material:
> 7.5 - < 9.5 mPa s at 25 °C
Flash point:
104 °C
Atm. press.:
1 013 hPa
Conclusions:
In a valid guideline study the flash point is reported to be 104 °C at 1013 hPa (Pensky Martens closed cup).
Executive summary:

In a valid guideline study the flash point is reported to be 104 °C at 1013 hPa (Pensky Martens closed cup).

Description of key information

In a valid guideline study the flash point is reported to be 104 °C at 1013 hPa

(Pensky Martens closed cup). (Evonik Röhm GmbH, 2008)

Key value for chemical safety assessment

Flash point at 101 325 Pa:
104 °C

Additional information