Registration Dossier
Registration Dossier
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 907-131-0 | CAS number: -
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data

Toxicity to microorganisms
Administrative data
Link to relevant study record(s)
- Endpoint:
- activated sludge respiration inhibition testing
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Reliability:
- 2 (reliable with restrictions)
- Rationale for reliability incl. deficiencies:
- test procedure in accordance with national standard methods with acceptable restrictions
- Qualifier:
- according to guideline
- Guideline:
- ISO 8192 (Water quality - Test for inhibition of oxygen consumption by activated sludge for carbonaceous and ammonium oxidation)
- GLP compliance:
- no
- Analytical monitoring:
- no
- Vehicle:
- no
- Test organisms (species):
- activated sludge, domestic
- Details on inoculum:
- - Inoculum concentration of dry substance 1 g/l
- Name and location of sewage treatment plant where inoculum was collected:Lambsheim, Germany; stp treating predominantly municipal wastewater - Test type:
- static
- Water media type:
- freshwater
- Limit test:
- no
- Total exposure duration:
- 30 min
- Nominal and measured concentrations:
- nominal: 15, 150, 750, 1995 mg/L
- Key result
- Duration:
- 30 min
- Dose descriptor:
- other: EC20
- Effect conc.:
- > 1 995 mg/L
- Nominal / measured:
- nominal
- Conc. based on:
- test mat.
- Basis for effect:
- inhibition of total respiration
- Endpoint:
- activated sludge respiration inhibition testing
- Type of information:
- experimental study
- Adequacy of study:
- supporting study
- Reliability:
- 2 (reliable with restrictions)
- Rationale for reliability incl. deficiencies:
- other: Guideline study (non-GLP); Results published in peer-reviewed journal
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 209 (Activated Sludge, Respiration Inhibition Test
- Deviations:
- yes
- Remarks:
- Syntehtic sewage: 10-fold level of K2HPO4 (28.0 g/L); adjustment of pH to 7.0 with H3PO4
- GLP compliance:
- no
- Analytical monitoring:
- not required
- Vehicle:
- no
- Test organisms (species):
- activated sludge, domestic
- Details on inoculum:
- - Laboratory culture: yes (sampling was done one day prior to each test series)
- Method of cultivation: 9-L laboratory scale, semi-continuous activated sludge cylinder, 21 °C
- Preparation of inoculum for exposure: washing, aeration
- Pretreatment: supplemented daily with 50 mL synthetic sewage stock solution
- Initial biomass concentration: 4 g/L suspended solids - Test type:
- static
- Water media type:
- freshwater
- Total exposure duration:
- 3 h
- Test temperature:
- 20 ± 2 °C
- pH:
- 7.5 ± 0.5
- Details on test conditions:
- TEST SYSTEM
- Test vessel: 1-L bottle
- Type (delete if not applicable): open
- Material, size, headspace, fill volume: 500 mL
- Aeration: 0.5-1.0 L/h
- No. of vessels per concentration (replicates): 1
- No. of vessels per control (replicates): 2
- Biomass loading rate: 1.6 g/L
TEST MEDIUM / WATER PARAMETERS
- Source/preparation of dilution water: dionized water
OTHER TEST CONDITIONS
- Adjustment of pH: yes
EFFECT PARAMETERS MEASURED (with observation intervals if applicable) : respiration rate
TEST CONCENTRATIONS
- Spacing factor for test concentrations: no data - Reference substance (positive control):
- yes
- Remarks:
- 3,5-dichlorophenol
- Duration:
- 3 h
- Dose descriptor:
- EC50
- Effect conc.:
- > 1 000 mg/L
- Nominal / measured:
- nominal
- Conc. based on:
- act. ingr.
- Basis for effect:
- inhibition of total respiration
- Remarks:
- respiration rate
- Remarks on result:
- other: graphic analysis
- Validity criteria fulfilled:
- yes
Referenceopen allclose all
Test concentration |
Promotion of respiration |
[mg/L] |
[%] |
blank |
- |
15 |
- |
150 |
- |
750 |
17 |
1995 |
17 |
Description of key information
The inhibition of the degradation activity of activated sludge is not anticipated when introduced in appropriate low concentrations.
Key value for chemical safety assessment
Additional information
2,2'-(ethylenedioxy)diethanol 3,6,9-trioxaundecane-1,11-diol (EC 907-131-0) is a multi-constituent substance. The main constituents of EC 907-131-0 are triethylene glycol (TGE, CAS 112-27-6, 10-80% w/w) and tetraethylene glycol (Tetra-EG, CAS 112-60-7, 10-80% w/w). Since no data on the toxicity to aquatic organisms of the reaction mass of 2,2'-(ethylenedioxy)diethanol 3,6,9-trioxaundecane-1,11-diol are available, the assessment is based on the available data for the main components triethylene glycol (CAS 112-27-6) and tetraethylene glycol (112-60-7).
Since no data on the toxicity for aquatic algae are available for main constituents the read-across approach was performed. This read-across approach consists of the available experimental data for the structurally similar substance diethylene glycol (CAS 111-46-6).
The effect of DEG on the respiration activity of activated sludge for a wastewater treatment plant treating predominantly domestic sewage was investigated in two guideline studies. In a study following ISO 8192, which is equivalent to OECD 209, a 30 -min EC20 > 1995 mg/L was determined (BASF AG, 1982).
This result is also supported with the test conducted according to OECD Guidance 209 by Klecka et al. (1985). The 3 -h EC50 was determined to be > 1000 mg/L (nominal).
Based on the available read-across data for the structurally similar substance, it can be concluded that the inhibition of the degradation activity is not anticipated when the substance is introduced in appropriately low concentrations.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.