Registration Dossier

Diss Factsheets

Environmental fate & pathways

Hydrolysis

Currently viewing:

Administrative data

Link to relevant study record(s)

Description of key information

Hydrolysis: The substance was highly unstable with a half life in the order of minutes at pH 4, 7 and 9 and 20, 30 and 50°C, respectively. Instability increased as temperature and pH increased. . 

Key value for chemical safety assessment

Half-life for hydrolysis:
6.92 min
at the temperature of:
20 °C

Additional information

Hydrolysis as a function of pH was determined according to OECD test methods. The study was conducted at pH 4, 7 and 9 and at temperatures of 20 °C , 30 °C and 50 °C. The substance was highly unstable at pH 4, 7 and 9 and 20, 30 and 50°C, respectively. Instability increased as temperature and pH increased. The half life of the substance was in the order of minutes.