Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Viscosity

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
viscosity
Type of information:
experimental study
Adequacy of study:
key study
Study period:
28-August - 29-August 2008
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Remarks:
OECD 114, non GLP. Study performed and documented equivalent to GLP standards. Study according to relevant guideline.
Qualifier:
according to guideline
Guideline:
OECD Test Guideline 114 (Viscosity of Liquids)
Version / remarks:
according to DIN 51 562
Deviations:
no
GLP compliance:
no
Remarks:
Study performed and documented equivalent to GLP standards.
Type of method:
capillary viscometer (static)
Specific details on test material used for the study:
- Name of test material (as cited in study report): Isodecyl methacrylate
- Substance type: organic
- Physical state at room temperature: liquid
Key result
Temp.:
20°C
Parameter:
kinematic viscosity (in mm²/s)
Value:
3.56
Remarks on result:
other: kinematic viscosity
Temp.:
40°C
Parameter:
kinematic viscosity (in mm²/s)
Value:
2.3
Remarks on result:
other: kinematic viscosity

The kinematic viscosity of the test item was measured with a micro-Ubbelohde viscometer according to DIN 51 562 at 20°C and 40°C as preferred by the OECD Guideline 114 (“Viscosity of Liquids”).

Kinematic viscosity at 20°C : 3.56 mm²/s

Kinematic viscosity at 40°C : 2.30 mm²/s

Conclusions:
The kinematic viscosity of the test item was measured with a micro-Ubbelohde viscometer according to DIN 51 562 at 20°C and 40°C as preferred by the OECD Guideline 114 (“Viscosity of Liquids”)
Kinematic viscosity at 20°C : 3.56 mm²/s
Kinematic viscosity at 40°C : 2.30 mm²/s
Executive summary:

The kinematic viscosity of the test item was measured with a micro-Ubbelohde viscometer according to DIN 51 562 at 20°C and 40°C as preferred by the OECD Guideline 114 (“Viscosity of Liquids”).

Kinematic viscosity at 20°C : 3.56 mm²/s

Kinematic viscosity at 40°C : 2.30 mm²/s

NOTE: Any of data in this dataset are disseminated by the European Union on a right-to-know basis and this is not a publication in the same sense as a book or an article in a journal. The right of ownership in any part of this information is reserved by the data owner(s). The use of this information for any other, e.g. commercial purpose is strictly reserved to the data owners and those persons or legal entities having paid the respective access fee for the intended purpose.

Description of key information

Kinematic viscosity at 20°C : 3.56 mm²/s
Kinematic viscosity at 40°C : 2.30 mm²/s

Key value for chemical safety assessment

Viscosity:
3.56 mm²/s (static)
at the temperature of:
20 °C

Additional information

The kinematic viscosity of Isodecyl methacrylate was measured with a micro-Ubbelohde viscometer according to DIN 51 562 at

20°C and 40°C as preferred by the OECD Guideline 114 (“Viscosity of Liquids”).

Kinematic viscosity at 20°C : 3.56 mm²/s

Kinematic viscosity at 40°C : 2.30 mm²/s