Registration Dossier

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2010
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Standard test procedure followed, but no GLP in place
Qualifier:
according to guideline
Guideline:
ISO No., other: ASTM D 56
GLP compliance:
no
Type of method:
closed cup
Key result
Flash point:
< 0 °C
Atm. press.:
1 atm
Conclusions:
Under the conditions of this study a flash point below 0°C at 1 atm was determined for the test substance, Hydrocarbons, C6-C7, n-alkanes, isoalkanes, cyclics, <5% n-hexane.
Executive summary:

Under the conditions of this study a flash point below 0°C at 1 atm was determined for the test substance, Hydrocarbons, C6-C7, n-alkanes, isoalkanes, cyclics, <5% n-hexane.

Description of key information

The flash point of Hydrocarbons, C6-C7, n-alkanes, isoalkanes, cyclics, <5% n-hexane is below 0°C.

Key value for chemical safety assessment

Additional information

A value of < 0°C was measured using ASTM D 56 method by ExxonMobil Chemical (2010).