Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 215-695-8 | CAS number: 1344-43-0
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Toxicity to microorganisms
Administrative data
Link to relevant study record(s)
- Endpoint:
- activated sludge respiration inhibition testing
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- 2 February 2010 and 3 February 2010.
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- other: Conducted to GLP and a current guideline
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 209 (Activated Sludge, Respiration Inhibition Test
- Deviations:
- no
- Qualifier:
- according to guideline
- Guideline:
- EU Method C.11 (Biodegradation: Activated Sludge Respiration Inhibition Test)
- Deviations:
- no
- Qualifier:
- according to guideline
- Guideline:
- EPA OPPTS 850.6800 (Modified Activated Sludge, Respiration Inhibition Test for Sparingly Soluble Chemicals)
- Deviations:
- no
- GLP compliance:
- yes (incl. QA statement)
- Remarks:
- Date of GLP inspection: 15/09/2009 Date of Signature on GLP certificate: 26/11/2009
- Analytical monitoring:
- no
- Details on sampling:
- - Concentrations:
Activated sewage sludge was exposed to an aqueous dispersion of the test item at concentrations of 10, 32, 100, 320 and 1000 mg/l.
- Sampling method:
As each vessel reached 3 hours contact time an aliquot was removed from the conical flask and poured into the measuring vessel (250 ml darkened glass Biological Oxygen Demand (BOD) bottle) and the rate of respiration measured using a Yellow Springs dissolved oxygen meter fitted with a BOD probe. - Vehicle:
- no
- Details on test solutions:
- PREPARATION AND APPLICATION OF TEST SOLUTION
- Method:
For the purpose of the test, the test item was dispersed in water.
Amounts of test item (5, 16, 50, 160 and 500 mg) were each separately dispersed in approximately 250 ml of water and subjected to ultrasonication for approximately 15 minutes followed by prolonged mixing for 24 hours in order to maximise the dissolved test item concentration. All test vessels were shielded from the light during mixing. Synthetic sewage (16 ml), activated sewage sludge (200 ml) and water were added to a final volume of 500 ml to give the required concentrations of 10, 32, 100, 320 and 1000 mg/l.
The control group was maintained under identical conditions but not exposed to the test item.
- Controls:
For the purpose of the test a reference item, 3,5-dichlorophenol (Sigma-Aldrich Batch No. 04621CJ) was used. Two stock solutions of 50 and 160 mg/l were prepared by dissolving the reference item directly in water with the aid of ultrasonication for approximately 20 minutes. Aliquots (10 and 100 ml) of the 160 mg/l stock solution were removed and dispersed with activated sewage sludge, synthetic sewage and water to give the final concentrations of 3.2 and 32 mg/l. Similarly, a 100 ml aliquot of the 50 mg/l stock solution was used to prepare the 10 mg/l concentration. The volumetric flasks containing the reference item were inverted several times to ensure homogeneity of the solutions. - Test organisms (species):
- activated sludge of a predominantly domestic sewage
- Details on inoculum:
- - Method of cultivation:
A mixed population of activated sewage sludge micro-organisms was obtained on 3 February 2010 from the aeration stage of the Severn Trent Water Plc sewage treatment plant at Loughborough, Leicestershire, UK which treats predominantly domestic sewage.
- Preparation of inoculum for exposure:
The activated sewage sludge sample was maintained on continuous aeration in the laboratory at a temperature of approximately 21ºC and was used on the day of collection. The pH of the sample was 7.2 measured using a WTW pH/Oxi 340I pH and dissolved oxygen meter. Determination of the suspended solids level of the activated sewage sludge was carried out by filtering a sample (100 ml) of the activated sewage sludge by suction through a pre-weighed GF/A filter paper using a Buchner funnel which was then rinsed 3 times with 10 ml of deionised reverse osmosis water and filtration continued for 3 minutes. The filter paper was then dried in an oven at approximately 105ºC for at least 1 hour and allowed to cool before weighing. This process was repeated until a constant weight was attained. The suspended solids concentration was equal to 3.7 g/l prior to use. - Test type:
- static
- Water media type:
- freshwater
- Limit test:
- no
- Total exposure duration:
- 3 h
- Post exposure observation period:
- Observations were made on the test preparations throughout the test period. Observations of the test item vessels at 0 hours were made prior to addition of activated sewage sludge and synthetic sewage. The pH of the control, reference item and test item preparations were measured using a WTW pH/Oxi 340I pH and dissolved oxygen meter at 0 hours and prior to measurement of the oxygen consumption rate after 3 hours contact time.
- Hardness:
- Water with a total hardness of approximately 140 mg/l as CaCO3.
- Test temperature:
- The test was conducted under normal laboratory lighting in a temperature controlled room at 21±1°C.
- pH:
- The pH of the control, reference item and test item preparations were measured using a WTW pH/Oxi 340I pH and dissolved oxygen meter at 0 hours and prior to measurement of the oxygen consumption rate after 3 hours contact time.
pH range for test items: 7.5 - 7.7 - Dissolved oxygen:
- The pH of the control, reference item and test item preparations were measured using a WTW pH/Oxi 340I pH and dissolved oxygen meter at 0 hours and prior to measurement of the oxygen consumption rate after 3 hours contact time.
- Salinity:
- Not applicable.
- Nominal and measured concentrations:
- Nominal concentrations of 10, 32, 100, 320 and 1000 mg/l.
- Details on test conditions:
- TEST SYSTEM
At time "0" 16 ml of synthetic sewage was diluted to 300 ml with water and 200 ml of inoculum added in a 500 ml conical flask (first control). The mixture was aerated with clean, oil-free compressed air via narrow bore glass tubes at a rate of approximately 0.5 – 1 litre per minute. Thereafter, at 15 minute intervals the procedure was repeated with appropriate amounts of the reference item being added. Finally a second control was prepared.
As each vessel reached 3 hours contact time an aliquot was removed from the conical flask and poured into the measuring vessel (250 ml darkened glass Biological Oxygen Demand (BOD) bottle) and the rate of respiration measured using a Yellow Springs dissolved oxygen meter fitted with a BOD probe. The contents of the measuring vessel were stirred constantly by magnetic stirrer. The rate of respiration for each flask was measured over the linear portion of the oxygen consumption trace (where possible between approximately 6.5 mg O2/l and 2.5 mg O2/l). In the case of a rapid oxygen consumption, measurements may have been outside this range but the oxygen consumption was always within the linear portion of the respiration curve. In the case of low oxygen consumption, the rate was determined over an approximate 10 minute period.
The test was conducted under normal laboratory lighting in a temperature controlled room at 21±1°C.
TEST MEDIUM / WATER PARAMETERS
- Source/preparation of dilution water:
The test water used for the definitive test was laboratory tap water dechlorinated by passage through an activated carbon filter (Purite Series 500) and partly softened (Elga Nimbus 1248D Duplex water softener) giving water with a total hardness of approximately 140 mg/l as CaCO3. After dechlorination and softening the water was then passed through a series of computer controlled plate heat exchangers to achieve the required temperature. Typical water quality characteristics for the tap water as supplied, prior to dechlorination and softening, are given in Appendix 1 (see attached background material).
- Total organic carbon: 1.018 mg/l
- Chlorine: 0.307 mg/l
- Conductivity: 386.192 μS/cm at 20°C
- Culture medium different from test medium: No
OTHER TEST CONDITIONS
A synthetic sewage of the following composition, was added to each test vessel to act as a respiratory substrate:
16 g Peptone
11 g Meat extract
3 g Urea
0.7 g NaCl
0.4 g CaCl2.2H2O
0.2 g MgSO4.7H2O
2.8 g K2HPO4
dissolved in 1 litre of water with the aid of ultrasonication.
EFFECT PARAMETERS MEASURED (with observation intervals if applicable) :
The rate of respiration was determined after 3 hours contact time and compared to data for the control and a reference item, 3,5-dichlorophenol.
TEST CONCENTRATIONS
- Range finding study: No range finding study. - Reference substance (positive control):
- yes
- Remarks:
- 3,5-dichlorophenol
- Duration:
- 3 h
- Dose descriptor:
- EC50
- Effect conc.:
- > 1 000 mg/L
- Nominal / measured:
- nominal
- Conc. based on:
- test mat.
- Basis for effect:
- growth inhibition
- Remarks on result:
- other: No 95% CL
- Duration:
- 3 h
- Dose descriptor:
- NOEC
- Effect conc.:
- 1 000 mg/L
- Nominal / measured:
- nominal
- Conc. based on:
- test mat.
- Basis for effect:
- growth inhibition
- Remarks on result:
- other: No 95% CL
- Details on results:
- Oxygen consumption rates and percentage inhibition values for the control, test and reference items are given in Table 1. The pH values of the test preparations at the start and end of the exposure period are given in Table 2, and observations made on the test preparations throughout the study are given in Table 3.
The following results were derived:
3 hour EC20: >1000 mg/l
3 hour EC50: >1000 mg/l
3 hour EC80: > 1000 mg/l
3 hour NOEC: 1000 mg/l
It was considered unnecessary and unrealistic to test at concentrations in excess of 1000 mg/l.
Variation in respiration rates of controls 1 and 2 after 3 hours contact time was ± 3%.
The validation criteria for the control respiration rates and reference item EC50 values were therefore satisfied.
In some instances, the initial and final dissolved oxygen concentrations were below those recommended in the test guidelines (6.5 mg O2/l and 2.5 mg O2/l respectively). This was considered to have had no adverse effect on the results of the study given that in all cases the oxygen consumption rate was determined over the linear portion of the oxygen consumption trace.
Observations made at 0 hours, 30 minutes and 3 hours (see Table 3) showed that the control vessels contained a dark brown dispersion and the reference item vessels contained a dark brown dispersion with no undissolved reference item visible.
Observations made at 0 hours prior to the addition of activated sewage sludge and synthetic sewage showed that the test concentrations of 10 and 32 mg/l contained a clear colourless water column with particles of test item on the bottom of the flask and the test concentration of 100 mg/l contained a pale brown dispersion with particles of test item on the surface and bottom of the flask. The test concentrations of 320 and 1000 mg/l contained a brown dispersion with particles of test item on the surface and bottom of the flask.
Observations made after 30 minutes and 3 hours contact time for the test concentration of 10 mg/l showed the vessel contained a dark brown dispersion with no undissolved test item visible and the test concentrations of 32 and 100 mg/l contained a dark brown dispersion with few particles of test item visible dispersed throughout. The test concentrations of 320 and 1000 mg/l contained a dark brown dispersion with particles of test item visible dispersed throughout. - Results with reference substance (positive control):
- Percentage inhibition is plotted against concentration for the reference item, 3,5 dichlorophenol only (Figure 1 - attached background material).
The following results were derived for 3,5-dichlorophenol
3 hour EC20: 3.2 mg/l
3 hour EC50: 9.7 mg/l (95% Confidence limits 8.0 - 12 mg/l)
3 hour EC80: 29 mg/l
3 hour NOEC: 2.7 mg/l - Reported statistics and error estimates:
- Variation in respiration rates of controls 1 and 2 after 3 hours contact time was ± 3%.
The validation criteria for the control respiration rates and reference item EC50 values were therefore satisfied. - Validity criteria fulfilled:
- yes
- Conclusions:
- The effect of the test item on the respiration of activated sewage sludge micro-organisms gave a 3-Hour EC50 of greater than 1000 mg/l. The No Observed Effect Concentration (NOEC) after 3 hours exposure was 1000 mg/l.
- Executive summary:
This was chosen as Key study as it is the only available study which is of relevance and of sufficient quality for classification and labelling and for risk assessment.
Introduction.
A study was performed to assess the effect of the test item on the respiration of activated sewage sludge. The method followed that described in the OECD Guidelines for Testing of Chemicals (1984) No 209 "Activated Sludge, Respiration Inhibition Test", Method C.11 of Commission Regulation (EC) No. 440/2008 and US EPA Draft Ecological Effects Test Guidelines OPPTS 850.6800.
Methods.
Activated sewage sludge was exposed to an aqueous dispersion of the test item at concentrations of 10, 32, 100, 320 and 1000 mg/l for a period of 3 hours at a temperature of approximately 21°C with the addition of a synthetic sewage as a respiratory substrate.
The rate of respiration was determined after 3 hours contact tiand compared to data for the control and a reference item, 3,5-dichlorophenol.
Results.
The effect of the test item on the respiration of activated sewage sludge gave a 3‑Hour EC50of greater than 1000 mg/l. The No Observed Effect Concentration (NOEC) after 3 hours exposure was 1000mg/l.
It was considered unnecessary and unrealistic to test at concentrations in excess of 1000 mg/l.
The reference item gave a 3-Hour EC50value of 9.7 mg/l, 95% confidence limits 8.0 - 12 mg/l.
Reference
Table 1 Oxygen Consumption Rates and Percentage Inhibition Values after 3 Hours Contact Time
Nominal Concentration (mg/l) |
Initial O2 Reading (mg O2/l) |
Measurement Period (minutes) |
Final O2Reading (mg O2/l) |
O2Consumption Rates (mg O2/l/min) |
% Inhibition |
|
Control |
R1 |
5.5 |
7 |
1.7 |
0.54 |
- |
|
R2 |
5.1 |
6 |
1.7 |
0.57 |
- |
Test item |
10 |
5.0 |
4 |
2.6 |
0.60 |
[8] |
|
32 |
4.5 |
4 |
2.2 |
0.58 |
[5] |
|
100 |
4.9 |
4 |
2.5 |
0.60 |
[8] |
|
320 |
5.4 |
5 |
2.5 |
0.58 |
[5] |
|
1000 |
5.4 |
5 |
2.6 |
0.56 |
[1] |
3,5-dichlorophenol |
3.2 |
6.0 |
9 |
2.0 |
0.44 |
21 |
|
10 |
7.0 |
10 |
4.1 |
0.29 |
48 |
|
32 |
7.9 |
10 |
7.0 |
0.09 |
84 |
[Increase in respiration rate as compared to controls]
R1– R2= Replicates 1 to 2
Table 2 pH Values of the Test Preparations at the Start and End of the Exposure Period
Nominal Concentration (mg/l) |
pH |
||
0 Hours |
3 Hours |
||
Control |
R1 |
7.2 |
7.9 |
|
R2 |
7.5 |
7.7 |
Test item |
10 |
7.6 |
7.7 |
|
32 |
7.6 |
7.7 |
|
100 |
7.6 |
7.7 |
|
320 |
7.6 |
7.7 |
|
1000 |
7.5 |
7.7 |
3,5-dichlorophenol |
3.2 |
7.5 |
7.9 |
|
10 |
7.5 |
8.0 |
|
32 |
7.5 |
8.1 |
R1– R2= Replicates 1 to 2
Table 3 Observations on the Test Preparations Throughout the Test Period
Nominal Concentration (mg/l) |
Observations on Test Preparations |
|||
0 Hours |
30 Minutes Contact Ti |
3 Hours Contact Ti |
||
Control |
R1 |
Dark brown dispersion |
Dark brown dispersion |
Dark brown dispersion |
|
R2 |
Dark brown dispersion |
Dark brown dispersion |
Dark brown dispersion |
Test item |
10 |
Clear colourless water column, particles of test item on bottom of flask[*] |
Dark brown dispersion, no undissolved test item visible |
Dark brown dispersion, no undissolved test item visible |
|
32 |
Clear colourless water column, particles of test item on bottom of flask* |
Dark brown dispersion, few particles of test item visible dispersed throughout |
Dark brown dispersion, few particles of test item visible dispersed throughout |
|
100 |
Pale brown dispersion, particles of test item on surface and on bottom of flask* |
Dark brown dispersion, few particles of test item visible dispersed throughout |
Dark brown dispersion, few particles of test item visible dispersed throughout |
|
320 |
Brown dispersion, particles of test item on surface and on bottom of flask* |
Dark brown dispersion, particles of test item visible dispersed throughout |
Dark brown dispersion, particles of test item visible dispersed throughout |
|
1000 |
Brown dispersion, particles of test item on surface and on bottom of flask* |
Dark brown dispersion, particles of test item visible dispersed throughout |
Dark brown dispersion, particles of test item visible dispersed throughout |
3,5-dichlorophenol |
3.2 |
Dark brown dispersion, no undissolved reference item visible |
Dark brown dispersion, no undissolved reference item visible |
Dark brown dispersion, no undissolved reference item visible |
|
10 |
Dark brown dispersion, no undissolved reference item visible |
Dark brown dispersion, no undissolved reference item visible |
Dark brown dispersion, no undissolved reference item visible |
|
32 |
Dark brown dispersion, no undissolved reference item visible |
Dark brown dispersion, no undissolved reference item visible |
Dark brown dispersion, no undissolved reference item visible |
R1– R2= Replicates 1 to 2
[*]Observations made prior to the addition of synthetic sewage and activated sewage sludge
Description of key information
The effect of the test item on the respiration of activated sewage sludge micro-organisms gave a 3-Hour EC50 of greater than 1000 mg/l. The No Observed Effect Concentration (NOEC) after 3 hours exposure was 1000 mg/l.
Key value for chemical safety assessment
Additional information
This was chosen as Key study as it is the only available study which is of relevance and of sufficient quality for classification and labelling and for risk assessment.
Introduction.
A study was performed to assess the effect of the test item on the respiration of activated sewage sludge. The method followed that described in the OECD Guidelines for Testing of Chemicals (1984) No 209 "Activated Sludge, Respiration Inhibition Test", Method C.11 of Commission Regulation (EC) No. 440/2008 and US EPA Draft Ecological Effects Test Guidelines OPPTS 850.6800.
Methods.
Activated sewage sludge was exposed to an aqueous dispersion of the test item at concentrations of 10, 32, 100, 320 and 1000 mg/l for a period of 3 hours at a temperature of approximately 21°C with the addition of a synthetic sewage as a respiratory substrate.
The rate of respiration was determined after 3 hours contact tiand compared to data for the control and a reference item, 3,5-dichlorophenol.
Results.
The effect of the test item on the respiration of activated sewage sludge gave a 3‑Hour EC50of greater than 1000 mg/l. The No Observed Effect Concentration (NOEC) after 3 hours exposure was1000mg/l.
It was considered unnecessary and unrealistic to test at concentrations in excess of 1000 mg/l.
The reference item gave a 3-Hour EC50value of 9.7 mg/l, 95% confidence limits 8.0 - 12 mg/l.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.