Registration Dossier

Diss Factsheets

Guidance on Safe Use

Guidance on Safe Use

Currently viewing:

Administrative data

First-aid measures

Immediately remove any clothing soiled by the product.
In case of burns, immediately cool affected skin for as long as possible with cold water. Do not remove clothing adhering to skin.
In case of unconsciousness place patient stably in side position for transportation.

Fire-fighting measures

Substance is not combustible.
In large surrounding fires all extiguishing media can be used.

Accidental release measures

Do not flush into surface water or sanitary sewer system.
Inform respective authorities in case of seepage into water course or sewage system.
Keep contaminated washing water and dispose of appropriately.

Handling and storage

Keep containers tightly sealed.
Store in a cool location.
Sore away from combustible materials.

Transport information

Land transport (UN RTDG/ADR/RID)

UN number:
1494
Shippingopen allclose all
Labels:
5.1
SpecialProvisionsopen allclose all

Inland waterway transport (UN RTDG/ADN(R))

UN number:
1494
Shippingopen allclose all
Labels:
5.1
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

UN number:
1494
Shipping information
Proper shipping name and description:
Sodium bromate
Chemical name:
Sodium bromate
Labels:
5.1
Remarksopen allclose all

Air transport (UN RTDG/ICAO/IATA)

UN number:
1494
Shipping information
Proper shipping name and description:
Sodium bromate
Chemical name:
Sodium bromate
Labels:
5.1
Remarksopen allclose all
SpecialProvisionsopen allclose all

Exposure controls / personal protection

1. Technical protection measures
Keep containers tightly closed. Avoid formation of dust

2. Organisational protection measures
Only trained personnell may handle the material.

3. Hand protection
Rubber gloves

4. Feet protection
Rubber boots

5. Body protection
Use protective suit with self-contained breathing apparatus.

6. Eye protection
Safety glasses

7. Respiratory protection
Particle filter

Stability and reactivity

Stable at normal conditions.
Oxidising matrial.

Disposal considerations

EWC-no.: 06 03 99
Discharge into waste water channels and biological treatment plants only after clearence with the operating company and in accordance with local Authority approval.