Registration Dossier

Physical & Chemical properties

Auto flammability

Currently viewing:

Administrative data

Link to relevant study record(s)

Description of key information

The auto-ignition temperature was determined by heating aliquots of the test item in a flask and observing for any ignition. Testing was conducted using a procedure designed to be compatible with Method A15 Auto-Ignition Temperature (Liquids and Gases) ofCommissionRegulation (EC) No 440/2008 of 30 May 2008.
The test item has been determined not to have an auto-ignition temperature below 400°C.

Key value for chemical safety assessment

Additional information

A reliability rating of 1 was assigned to the key study, according to the criteria of Klimisch, 1997 as the study was conducted in accordance with recognised guidelines and GLP.