Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Auto flammability

Currently viewing:

Administrative data

Endpoint:
auto-flammability
Type of information:
experimental study
Adequacy of study:
supporting study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: GLP compliant, guideline study,.available as an unpublished report, reliable without restriction.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2010

Materials and methods

Test guideline
Qualifier:
equivalent or similar to guideline
Guideline:
other: Method N.4 of the UN Transport of Dengerous Goods, Manual of Tests and Criteria, fourth revised edition, 2003.
Deviations:
yes
Remarks:
Due to limited volume of test item available a modified method was used.
Principles of method if other than guideline:
Temperature of test item aliquot heated in oven. Temperature of over and centre of test item constantly monitored with thermocouples for signs of self heating.
GLP compliance:
yes (incl. QA statement)

Test material

Constituent 1
Reference substance name:
Materials for reclaim, precious metal on bricks, crucibles, trays, etc
IUPAC Name:
Materials for reclaim, precious metal on bricks, crucibles, trays, etc
Details on test material:
- Name of test material: Refinable No 9.2: Materials for reclaim, precious metal on bricks, crucibles, trays, etc.
- Physical state: Dark grey/light grey lumps
- Lot/batch number: AABRICKS and 14052010PC
- Expiry date: 2030
- Storage condition of test material: Room temperature in the dark

Results and discussion

Auto-ignition temperature (liquids / gases)
Remarks on result:
other: No self-heating of the substance was observed up to 400°C
Relative self-ignition temperature (solids)
Remarks on result:
other: No self-heating of the substance was observed up to 400°C

Any other information on results incl. tables

There were no signs of self-ignition or self heating over the duration of the test.

Applicant's summary and conclusion

Conclusions:
The substance was heated up to 400°C. There were no signs of self-ignition or self-heating over the duration of the test.
Executive summary:

In a GLP-compliant, guideline test the substance was heated up to 400°C. There were no signs of self-ignition or self-heating over the duration of the test.