Registration Dossier

Physical & Chemical properties

Auto flammability

Currently viewing:

Administrative data

Endpoint:
auto-flammability
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: GLP guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2010
Report Date:
2010

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
EU Method A.15 (Auto-Ignition Temperature (Liquids and Gases))
Principles of method if other than guideline:
Auto-flammability behaviour of gases and vapours is determined
using the apparatus described in EN 14522
GLP compliance:
yes (incl. certificate)

Test material

Reference
Name:
Unnamed
Type:
Constituent
Details on test material:
Name of test material (as cited in study report): 2-Ethylhexanoyl Chloride
Analytical purity: 99,0%
Lot/batch No.: 000STD77LO

Results and discussion

Auto-ignition temperature (liquids / gases)
Auto-ignition temperature:
246 °C
Atm. press.:
1 016 - 1 018 mBar
Remarks on result:
other:

Any other information on results incl. tables

Test run no.

lowest

temperature
[°C]

quantity of sample
[mg]
ignition delay time
[s]
1st test series 250 0,08 14
2nd test series 265 0,08 7
3rd test series 251 0,08 12
4th test series 256 0,08 9
5th test series 261 0,08 8

The tests were performed at an atmospheric pressure of 1016 mbar - 1018 mbar.

From these test runs a corrected* auto-ignition-temperature of 246 °C results.

* Correction performed according to EN 14522.

Applicant's summary and conclusion