Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

First-aid measures

Skin contact: Wash off immediately with plenty of soap and water.
Eye contact: Rinse immediately with plenty of water for 15 minutes holding the eyelids open.
Inhalation: Move the exposed person to fresh air.
Ingestion: Drink 1 to 2 glasses of water. If ingested, induce vomiting, but only under medical supervision

Fire-fighting measures

Extinguishing media: Use extinguishing media appropriate to the surrounding fire conditions.
Protective equipment: Wear suitable respiratory equipment when necessary.

Accidental release measures

Clean up methods: Clean spillage area thoroughly with plenty of water.

Handling and storage

Engineering measures: Ensure adequate ventilation of the working area.
Hand protection: Rubber gloves.
Eye protection: Approved safety goggles.
Protective equipment: Chemical resistant clothing.
Storage: Keep containers tightly closed.

Transport information

Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

Shippingopen allclose all
Remarksopen allclose all
Shippingopen allclose all
Remarksopen allclose all
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Hand protection: Rubber gloves.
Eye protection: Approved safety goggles.
Protective equipment: Chemical resistant clothing.

Stability and reactivity

Stability: Stable under normal conditions.
Conditions to avoid: Heat.
Materials to avoid: Strong oxidising agents.

Disposal considerations

Waste Disposal Methods:
- packing it in paper or other flammable material and burning in a suitable combustion chamber.
- By dissolving it in a flammable solvent and atomizing in a suitable combustion chamber.
Dispose of in compliance with all local and national regulations.