Registration Dossier

Administrative data

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
05 November 2010 to 19 November 2010
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: This study was conducted in accordance with international guidelines in a GLP facility.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2011
Report Date:
2011

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
EU Method A.9 (Flash-Point)
Deviations:
no
GLP compliance:
yes (incl. certificate)
Type of method:
equilibrium method closed cup

Test material

Reference
Name:
Unnamed
Type:
Constituent
Details on test material:
Identification: 3-trifluoromethylaniline
Description: Extremely pale yellow liquid
Purity: 99.66 %
Batch Number: 101009
Date Received: 25 October 2010
Storage Conditions: Room storage in the dark

Results and discussion

Flash point
Flash point:
85.072 °C
Atm. press.:
101.01 kPa

Applicant's summary and conclusion

Conclusions:
The flash point of the test item has been determined to be 85 +/- 2 degrees celsius.