Registration Dossier

Physical & Chemical properties

Viscosity

Currently viewing:

Administrative data

Endpoint:
viscosity
Type of information:
experimental study
Adequacy of study:
other information
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: National guideline study with acceptable restrictions: reporting deficiencies

Data source

Reference
Reference Type:
other company data
Title:
Unnamed
Year:
2006
Report Date:
2006

Materials and methods

Principles of method if other than guideline:
kinetic viscosity according to DIN 51562
dynamic viscosity according to DIN 53019
flow-time according to ISO2431
The test substance is not of highest available purity grade.
GLP compliance:
not specified
Type of method:
other: see below

Test material

Reference
Name:
Unnamed
Type:
Constituent
Details on test material:
- Name of test material (as cited in study report): o-Chloranilin, roh

- Physical state: liquid
- Analytical purity: >97%

Results and discussion

Viscosityopen allclose all
Temp.:
20°C
Parameter:
kinematic viscosity (in mm²/s)
Value:
2.64
Remarks on result:
other: kinetic viscosity
Temp.:
20°C
Parameter:
dynamic viscosity (in mPa s)
Value:
3.2
Remarks on result:
other: dynamic viscosity
Temp.:
20°C
Parameter:
other: sec
Value:
< 30
Remarks on result:
other: flow-time; 3 mm ISO-Becher

Any other information on results incl. tables

no further data

Applicant's summary and conclusion

Executive summary:

Heitkamp, 2006

kinetic viscosity according to DIN 51562: 2.64 mm²/sec

dynamic viscosity according to DIN 53019: 3.2 mPas

flow-time according to ISO2431: < 30 sec