Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Boiling point

Currently viewing:

Administrative data

Link to relevant study record(s)

Referenceopen allclose all

Endpoint:
boiling point
Type of information:
experimental study
Adequacy of study:
weight of evidence
Reliability:
4 (not assignable)
Rationale for reliability incl. deficiencies:
data from handbook or collection of data
Justification for type of information:
Due to insufficient reporting of the experimental details, this study was rated with a Klimisch score of 4 (‘not assignable’). As none of the available studies can serve as a key study with a sufficiently detailed reporting justifying a Klimisch score of 1 or 2 for the given endpoint, several independent sources were used in a weight of evidence approach. The combined data from handbooks or collection of data provide experimental values in a similar range, supporting the reliability of the result.
Principles of method if other than guideline:
secondary peer reviewed source, valid collection of data
GLP compliance:
not specified
Specific details on test material used for the study:
- Name of test material (as cited in study report): o-Nitrotoluene
- Analytical purity: not specified
Boiling pt.:
222 °C
Atm. press.:
1 013 hPa
Executive summary:

Roempp, 2009


The boiling point of 2-nitrotoluene was reported a s 222 °C at 1013 hPa.

Endpoint:
boiling point
Type of information:
experimental study
Adequacy of study:
weight of evidence
Reliability:
4 (not assignable)
Rationale for reliability incl. deficiencies:
data from handbook or collection of data
Justification for type of information:
Due to insufficient reporting of the experimental details, this study was rated with a Klimisch score of 4 (‘not assignable’). As none of the available studies can serve as a key study with a sufficiently detailed reporting justifying a Klimisch score of 1 or 2 for the given endpoint, several independent sources were used in a weight of evidence approach. The combined data from handbooks or collection of data provide experimental values in a similar range, supporting the reliability of the result.
Principles of method if other than guideline:
secondary peer reviewed source, valid collection of data
GLP compliance:
not specified
Specific details on test material used for the study:
- Analytical purity: not specified
Boiling pt.:
222.3 °C
Atm. press.:
1 010 hPa
Executive summary:

Booth G (Ullmann), 2009


The boiling point of 2-nitrotoluene was reported a s 222.3 °C at 1010 hPa.

Endpoint:
boiling point
Type of information:
experimental study
Adequacy of study:
weight of evidence
Reliability:
4 (not assignable)
Rationale for reliability incl. deficiencies:
data from handbook or collection of data
Principles of method if other than guideline:
secondary peer reviewed source, valid collection of data
GLP compliance:
not specified
Specific details on test material used for the study:
- Analytical purity: not specified
Key result
Boiling pt.:
220.4 °C
Remarks on result:
other: atmospheric pressure was not reported

atmospheric pressure was not reported

Executive summary:

Merck Index, 2006


The boiling point of 2-nitrotoluene was reported as 220.4 °C. Atmospheric pressure was not reported.

Description of key information

The individual study reports (data from handbooks or collection of data) show some deficiencies with respect to the comprehensiveness of the experimental details. Therefore, a reliability of 1 or 2 and thus adequacy as key study was not assignable for any of the individual studies. Consequently, the studies were assigned a Klimisch score of 4 (according to guidance document R.4, ‘not assignable: studies or data […] which are only listed in short abstracts or secondary literature (books, reviews, etc.)). As the individual studies report values are in a similar range, collectively, these studies can be used to conclude on this endpoint and to satisfy the information requirement.


The boiling point of 2-Nitrotoluene was determined in a series of experimental studies and found to be in the range of 220.4 - 222.3 °C:


Roempp, 2009: The boiling point of 2-nitrotoluene was reported as 222 °C at 1013 hPa.


Booth G (Ullmann), 2009: The boiling point of 2-nitrotoluene was reported as 222.3 °C at 1010 hPa.


Merck Index, 2006: The boiling point of 2-nitrotoluene was reported as 220.4 °C. Atmospheric pressure was not reported.


 


The reported boiling point by ROEMPP 2009 was chosen as the key value, because it was measured at normal pressure.

Key value for chemical safety assessment

Boiling point at 101 325 Pa:
222 °C

Additional information