Registration Dossier

Administrative data

Endpoint:
boiling point
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: GLP study according to EU / OECD guideline.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2011

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
OECD Guideline 103 (Boiling point/boiling range)
GLP compliance:
yes (incl. certificate)
Type of method:
differential scanning calorimetry

Test material

Reference
Name:
Unnamed
Type:
Constituent
Test material form:
other: solid

Results and discussion

Boiling point
Atm. press.:
101.3 kPa
Decomp. temp.:
>= 255 - <= 315 °C
Remarks on result:
other: The test item had no boiling point at atmospheric pressure. It decomposed first.

Applicant's summary and conclusion

Conclusions:
The test item had no boiling point at atmospheric pressure. It decomposed first.