Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Toxicological information

Eye irritation

Currently viewing:

Administrative data

Endpoint:
eye irritation: in vitro / ex vivo
Type of information:
experimental study
Adequacy of study:
key study
Study period:
18-feb-2010
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: The study has been performed according to OECD and/or EC guidelines and according to GLP principles.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2010
Report date:
2010

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
other: OECD guideline 437 (Bovine corneal opacity and permeability (BCOP) test method for identifying ocular corrosives and severe irritants )
Deviations:
no
GLP compliance:
yes (incl. QA statement)

Test material

Constituent 1
Reference substance name:
Linseed oil, oxidized
EC Number:
272-038-8
EC Name:
Linseed oil, oxidized
Cas Number:
68649-95-6
Molecular formula:
Not applicable (a generic molecular formula cannot be provided for this specific UVCB substance).
IUPAC Name:
Oxidation products of seed oil obtained from Linum usitatissimum, Linaceae (linseed)
Details on test material:
- Name of test material (as cited in study report): Blown linseed oil
- Substance type: Hazy yellow to brown liquid
- Physical state: liquid
- Stability under test conditions: Stable
- Storage condition of test material: At room temperature in the dark

Test system

Amount / concentration applied:
TEST MATERIAL
- Amount(s) applied (volume or weight with unit): 750 µl per cornea

NEGATIVE CONTROL
- Amount(s) applied (volume or weight with unit): 750 µl of physiological saline per cornea

POSITIVE CONTROL
Amount(s) applied (volume or weight with unit): 750 µl per cornea
Concentration (if solution): 10% (w/v) Benzalkonium Chloride
Duration of treatment / exposure:
- Exposure: 10 minutes
- Post incubation period: 120 minutes
Details on study design:
TEST SITE
- Isolated bovine cornea

REMOVAL OF TEST SUBSTANCE
- Washing (if done): yes
- Time after start of exposure: 10 minutes

SCORING SYSTEM:
- The mean opacity and mean permeability values (OD490) were used for each treatment group to calculate an in vitro score:

In vitro irritancy score (IVIS) = mean opacity value + (15 x mean OD490 value).

TOOL USED TO ASSESS SCORE:
- opacitymeter and microplate reader

DATA EVALUATION:
- A test substance that induces an IVIS ≥ 55.1 is defined as a corrosive or severe irritant

Results and discussion

In vitro

Results
Irritation parameter:
in vitro irritation score
Run / experiment:
10 minutes
Value:
0
Vehicle controls validity:
not applicable
Negative controls validity:
valid
Positive controls validity:
valid
Remarks on result:
no indication of irritation
Other effects / acceptance of results:
The individual in vitro irritancy scores for the negative controls was 0 for all three corneas. The individual positive control in vitro irritancy scores ranged from 119 to 162 for Benzalkonium Chloride

Applicant's summary and conclusion

Interpretation of results:
not irritating
Remarks:
based on Annex I of 1272/2008/EC (CLP)
Conclusions:
The negative control responses of the opacity and permeability values were less than the upper limits of the laboratory historical range indicating that the negative control did not induce irritancy on the corneas. The mean in vitro irritancy score of the positive control (10% (w/v) Benzalkonium Chloride) was 136 and was within the historical positive control data range.

Blown linseed oil did not induce ocular irritation through both endpoints, resulting in a mean in vitro irritancy score of 0 after 240 minutes of treatment.

Finally, it is concluded that this test is valid and that Blown linseed oil is not irritant in the Bovine Corneal Opacity and Permeability test under the experimental conditions described in the report.