Endpoint:
oxidising liquids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Recent guideline study not to GLP
Qualifier:
according to guideline
Guideline:
EU Method A.21 (Oxidising Properties (Liquids))
Qualifier:
according to guideline
Guideline:
other: UN test method O.2
GLP compliance:
no
Contact with:
powdered cellulose
Key result
Sample tested:
test mixture (not specified)
Remarks:
migrated information
Parameter:
mean pressure rise time
Result:
27 693 ms
Sample tested:
reference mixture (not specified)
Remarks:
migrated information
Parameter:
mean pressure rise time
Result:
3 488 ms
Interpretation of results:
GHS criteria not met
Conclusions:
The substance is not classified as an oxidising substance.
Executive summary:

In a non-GLP study conducted in line with UN Test Method O.2, the test material is found to not have oxidising properties.

Description of key information

The substance is not classified as an oxidising substance.

Key value for chemical safety assessment

Oxidising properties:
no

Additional information

Justification for classification or non-classification