Registration Dossier

Administrative data

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: The flash point was determined accoridng to EU Method A.9 (Flash-Point) 1992.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2009
Report Date:
2009

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to
Guideline:
EU Method A.9 (Flash-Point)
Version / remarks:
1992
Deviations:
no
Qualifier:
according to
Guideline:
ISO 13736:1997 (Petroleum products and other liquids - Determination of flash point - Abel closed cup method)
Version / remarks:
1997. Remark: 1997
Deviations:
no
GLP compliance:
yes (incl. certificate)
Type of method:
closed cup
Remarks:
Abel method

Test material

Reference
Name:
Unnamed
Type:
Constituent
Type:
Constituent
Details on test material:
Details on Test material
- Name of test material (as cited in study report): Crotylchlorid
- Substance type: clear liquid
- Physical state: liquid
- Analytical purity: > 97.5%

Results and discussion

Flash point
Flash point:
-10.5 °C
Atm. press.:
>= 1 013 - <= 1 016 hPa

Applicant's summary and conclusion

Conclusions:
The flash point was determined accoridng to EU Method A.9 (Flash-Point) 1992 and according to DIN ISO 13736:1997.