Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 242-367-1 | CAS number: 18480-07-4
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Toxicity to other aquatic organisms
Administrative data
- Endpoint:
- toxicity to other aquatic vertebrates
- Type of information:
- experimental study
- Adequacy of study:
- supporting study
- Reliability:
- 3 (not reliable)
- Rationale for reliability incl. deficiencies:
- other: The paper itself provides little information on test methodology, measured Sr-levels are not reported, and the derived end parameters are not useful for risk assessment purposes.
Data source
Reference
- Reference Type:
- publication
- Title:
- Aquatic toxicology of trace elements of coal and fly ash
- Author:
- Birge WJ
- Year:
- 1 978
- Bibliographic source:
- In: Thorpe JH, Gibbons JW (Eds.), Energy and Environmental Stress in aquatic Systems. Department of Energy Symposium Series CONT 771114
Materials and methods
Test guideline
- Qualifier:
- no guideline available
- GLP compliance:
- not specified
Test material
- Reference substance name:
- strontium dichloride, hexahydrate
- IUPAC Name:
- strontium dichloride, hexahydrate
- Reference substance name:
- Strontium chloride hexahydrate
- EC Number:
- 600-046-7
- Cas Number:
- 10025-70-4
- Molecular formula:
- Cl2-Sr.6H2-O
- IUPAC Name:
- Strontium chloride hexahydrate
- Test material form:
- not specified
Constituent 1
Constituent 2
Sampling and analysis
- Analytical monitoring:
- yes
Test solutions
- Vehicle:
- not specified
Test organisms
- Test organisms (species):
- Gastrophryne carolinensis
- Details on test organisms:
- fertilised eggs
Study design
- Test type:
- semi-static
- Water media type:
- freshwater
- Limit test:
- no
- Total exposure duration:
- 7 d
Test conditions
- Hardness:
- 195 +/- 5.4 mg/L as CaCO3
- Test temperature:
- 22.0 +/-1 degrees Celsius
- pH:
- 7.4 +/- 1.0
- Dissolved oxygen:
- near saturation
- Nominal and measured concentrations:
- not reported; 10-14 concentrations were tested
- Details on test conditions:
- Exposure periods started upon fertilisation of the eggs and ended at 4 days post-hatching, indicating that test results should be considered as chronic tests
No further details are provided
Results and discussion
Effect concentrationsopen allclose all
- Duration:
- 7 d
- Dose descriptor:
- LC50
- Effect conc.:
- 160 µg/L
- Nominal / measured:
- meas. (not specified)
- Conc. based on:
- element
- Basis for effect:
- other: mortality and teratogenity
- Remarks on result:
- other: 120-210
- Duration:
- 7 d
- Dose descriptor:
- other: LC1
- Effect conc.:
- 2.4 µg/L
- Nominal / measured:
- meas. (not specified)
- Conc. based on:
- element
- Basis for effect:
- other: mortality and teratogenity
- Remarks on result:
- other: 1.0-4.6
- Details on results:
- Sr-levels were measured indicating that reported effect levels are based on measured values or are based on nominal values that were relevant for the actual metal concentration.
- Reported statistics and error estimates:
- log-probit analysis - method of Daum (1969)
Applicant's summary and conclusion
- Validity criteria fulfilled:
- not specified
- Conclusions:
- The paper itself provides little information on test methodology, measured Sr-levels are not reported, and the derived end parameters are not useful for risk assessment purposes.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.