Registration Dossier

Administrative data

Endpoint:
flammable gases
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
1988

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
EU Method A.11 (Flammability (Gases))

Test material

Reference
Name:
Unnamed
Type:
Constituent

Results and discussion

Flammable solids
Test procedure:
burning time (test type not further specified)
Remarks:
or specified in description of method (migrated information)
Burning time:
>= 300 - <= 600 s
Pyrophoric solids
Test procedure:
ignition time on contact with air
Remarks:
Ignition on contact with air refers to either Pyrophoric solids or Pyrophoric liquids depending on physical state (migrated information).
Remarks on result:
ignition on contact with air (not further specified)
Remarks:
corresponding to 'yes' in migrated source record.
Pyrophoric liquids
Test procedure:
ignition time on contact with air
Remarks:
Ignition on contact with air refers to either Pyrophoric solids or Pyrophoric liquids depending on physical state (migrated information).
Remarks on result:
ignition on contact with air (not further specified)
Remarks:
corresponding to 'yes' in migrated source record.

Applicant's summary and conclusion