Physical & Chemical properties

Density

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
relative density
Remarks:
Other density types indicated (migrated information): density
Type of information:
experimental study
Adequacy of study:
key study
Study period:
From June 02, 2012 to August 21, 2012
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: The study was well conducted in accordance with OECD 109, EU A.3 and US EPA 830.7300 guidelines as well as in compliance with GLP.
Qualifier:
according to guideline
Guideline:
OECD Guideline 109 (Density of Liquids and Solids)
Deviations:
no
Qualifier:
according to guideline
Guideline:
EU Method A.3 (Relative Density)
Deviations:
no
Qualifier:
according to guideline
Guideline:
EPA OPPTS 830.7300 (Density / Relative Density / Bulk Density)
Deviations:
no
GLP compliance:
yes
Remarks:
(OECD GLP)
Type of method:
pycnometer method
Type:
density
Density:
0.967 g/cm³
Temp.:
20 °C
Type:
relative density
Density:
0.967
Temp.:
20 °C

The results of the tests on the determination of the density of the test substance are given in Table1.

 

The individual measurements were obtained with a deviation of < 0.01 g/cm3. According to the guideline, the density of the test substance is given as the mean value.

Table1: Density of the test substance

 

Test 1

Test 2

Mean

 

 

 

 

Mass empty pycnometer (A)

31.3917 g

31.3918 g

31.39175 g

Mass pycnometer with water (B)

40.8082 g

40.8076 g

 

 

 

 

 

Volume of the pycnometer

9.4335 cm3

9.4328 cm3

9.4332 cm3

 

 

 

 

Mass pycnometer with test substance (C)

40.5177 g

40.5181 g

 

 

 

 

 

Density

0.9674 g/cm3

0.9675 g/cm3

0.967 g/cm3

 

 

 

 

 

Conclusions:
Under the conditions of the study, the test substance was determined to have a density and relative density of 0.967 g/cm3 and 0.967 respectively at 20°C.
Executive summary:

A study was conducted to determine the density of the test substance using a pycnometer according to the OECD 109, EU A.3 and US EPA 830.7300 guidelines. Under the conditions of the study, the test substance was determined to have a density and relative density of 0.967 g/cm3 and 0.967 respectively at 20°C.

Description of key information

The density was determined using a pycnometer according to OECD Guideline 109, EU Method A.3 and US EPA Guideline 830.7300 (Baltussen, 2012).

Key value for chemical safety assessment

Relative density at 20C:
0.967

Additional information