Registration Dossier

Administrative data

Endpoint:
explosiveness
Data waiving:
other justification
Justification for data waiving:
other:

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2013
Report Date:
2013

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
EU Method A.14 (Explosive properties)
Deviations:
no
GLP compliance:
no

Test material

Reference
Name:
Unnamed
Type:
Constituent
Details on test material:
Identification: BMS-528233-01
Description: white powder
BMS Batch Number: 2C80150N
Vendor Batch Number: LTBB2S1005
Structure: Please see Attachment 1 of this Summary
Molecular Formula: C17H27NO5
Molecular Weight: 325.41
Purity: 100%
Expiry Date: 31 January 2015
Storage Conditions: room temperature in the dark

Results and discussion

Small-scale preliminary testsopen allclose all
Parameter:
other: More sensitive to shock than m-dinitrobenzene
Remarks:
migrated information
Remarks on result:
other: no data
Remarks:
Not conducted
Parameter:
other: More sensitive to friction than m-dinitrobenzene
Remarks:
migrated information
Remarks on result:
other: no data
Remarks:
Not conducted
Parameter:
other: Explosive under influence of flame
Remarks:
migrated information
Remarks on result:
other: no data
Remarks:
Not conducted
Parameter:
other: Explosive (not specified)
Remarks:
migrated information
Remarks on result:
negative (not further specified)
Remarks:
Based on the oxygen balance of the test item

Any other information on results incl. tables

Results

The oxygen balance of the test item was calculated to be -209.

Applicant's summary and conclusion

Conclusions:
Based on the oxygen balance of the test item the result for the explosive properties has been predicted negative.
Executive summary:
The prediction was undertaken using a procedure designed to be compatible with Method A14 Explosive Properties of Commission Regulation (EC) No 440/2008 of 30 May 2008.

Results

The oxygen balance of the test item was calculated to be -209.

 

Conclusion

Based on the oxygen balance of the test item the result for the explosive properties has been predicted negative.