Registration Dossier

Administrative data

First-aid measures

If inhaled
- Move to fresh air.
- If symptoms persist, call a physician.

In case of eye contact
- Rinse thoroughly with plenty of water, also under the eyelids.
- If eye irritation persists, consult a specialist.

In case of skin contact
- Wash off with soap and water.

If swallowed
- Rinse mouth with water.
- Do NOT induce vomiting.

Fire-fighting measures

Suitable extinguishing media
- powder
- Foam
- Carbon dioxide (CO2)
- Water
- Water spray

Unsuitable extinguishing media
- None.

Specific hazards arising from the chemical
- Combustible material
- Hazardous decomposition products formed under fire conditions.
- Vapours may form explosive mixtures with air.

Special protective actions for fire-fighters
- In the event of fire, wear self-contained breathing apparatus.

Accidental release measures

Advice for non-emergency personnel
- Prevent further leakage or spillage if safe to do so.

Advice for emergency responders
- Use personal protective equipment.

Environmental precautions
- Should not be released into the environment.

Methods and materials for containment and cleaning up
- Dam up.
- Soak up with inert absorbent material.
- Prevent product from entering drains.
- Keep in properly labelled containers.
- Keep in suitable, closed containers for disposal.

Handling and storage

Precautions for safe handling
- Ensure adequate ventilation.

Storage
- Store in original container.
- Store in a well-ventilated place. Keep cool.
- Keep in properly labelled containers.
- Keep container closed.
- Keep in a bunded area.
- Keep away from heat/sparks/open flames/hot surfaces. - No smoking.
- Keep away from incompatible products

Transport information

Land transport (ADR/RID)

UN number:
not regulated
Shippingopen allclose all
SpecialProvisionsopen allclose all

Inland waterway transport (ADN(R))

UN number:
not regulated
Shippingopen allclose all
Remarksopen allclose all

Marine transport (IMDG)

UN number:
not regulated
Remarksopen allclose all

Air transport ICAO/IATA

UN number:
not regulated
Remarksopen allclose all
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Appropriate engineering controls
- Apply technical measures to comply with the occupational exposure limits.

Respiratory protection
- Not required; except in case of aerosol formation.
- Respirator with a vapour filter (EN 141)
- Recommended Filter type: A/P2

Hand protection
- Impervious gloves
- Suitable material: PVC
- Take note of the information given by the producer concerning permeability and break through times, and of special workplace conditions (mechanical strain, duration of contact).

Eye protection
- If splashes are likely to occur, wear:
- Goggles

Skin and body protection
- Long sleeved clothing

Hygiene measures
- When using do not eat, drink or smoke.
- Wash hands before breaks and at the end of workday.
- Handle in accordance with good industrial hygiene and safety practice.

Environmental exposure controls
- Dispose of rinse water in accordance with local and national regulations.

Stability and reactivity

Chemical stability
- Stable under recommended storage conditions.

Possibility of hazardous reactions
- Explosive when mixed with oxidizing substances.

Conditions to avoid
- To avoid thermal decomposition, do not overheat.
- Heat, flames and sparks.

Materials to avoid
- Oxidizing agents, Strong acids, Chlorine, Fluorine, Alcohol

Hazardous decomposition products
- Carbon monoxide

Disposal considerations

Waste disposal methods
- In accordance with local and national regulations.
- The organic ingredients can be biodegraded in a sewage plant after neutralization.
- Must be incinerated in a suitable incineration plant holding a permit delivered by the competent authorities.

Contaminated packaging
- Dispose of as unused product.
- Where possible recycling is preferred to disposal or incineration.