Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Explosiveness

Currently viewing:

Administrative data

Link to relevant study record(s)

Referenceopen allclose all

Endpoint:
explosive properties of explosives
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2001-03-22 to 2001-06-20
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.14 (Explosive properties)
GLP compliance:
yes (incl. QA statement)
Specific details on test material used for the study:
Batch: KP01/03
Purity: 96.6 % w/w
State: solid
Key result
Parameter:
thermal sensitivity - Koenen test: diameter of the orifice plate
Remarks on result:
not thermal sensitive if heated under defined confinement
Key result
Parameter:
sensitiveness to impact: impact energy (J)
Remarks on result:
not sensitive to impact using an impact energy of 40 J
Key result
Parameter:
sensitiveness to friction: friction load (N)
Remarks on result:
not sensitive to friction using a friction load of 360 N
Conclusions:
The test item is not sensitive to heat, shock and friction and therefore is not considered an explosive.
Executive summary:

The test item is not sensitive to heat, shock and friction and therefore is not considered an explosive. The test was performed according to EEC Guideline A.14.

Endpoint:
explosive properties of explosives
Remarks:
test whether a solid presents a danger of explosion
Type of information:
read-across from supporting substance (structural analogue or surrogate)
Adequacy of study:
key study
Justification for type of information:
For justification of read-across please refer to the read-across report attached to IUCLID section 13.
Reason / purpose for cross-reference:
read-across source
Key result
Parameter:
thermal sensitivity - Koenen test: diameter of the orifice plate
Remarks on result:
not thermal sensitive if heated under defined confinement
Key result
Parameter:
thermal sensitivity - Koenen test: limiting diameter (mm)
Remarks on result:
not sensitive to impact using an impact energy of 40 J
Key result
Parameter:
sensitiveness to friction: friction load (N)
Remarks on result:
not sensitive to friction using a friction load of 360 N
Conclusions:
The test item is not sensitive to heat, shock and friction and therefore is not considered an explosive.
Executive summary:

The test item is not sensitive to heat, shock and friction and therefore is not considered an explosive. The test was performed according to EEC Guideline A.14.

This information is used in a read-across approach in the assessment of the target substance. For justification of read-across please refer to the attached read-across report (see IUCLID section 13).

Description of key information

The test item is non explosive.

Key value for chemical safety assessment

Explosiveness:
non explosive

Additional information

This information is used in a read-across approach in the assessment of the target substance. For justification of read-across please refer to the attached read-across report (see IUCLID section 13).

Justification for classification or non-classification

The test item is not sensitive to heat, shock and friction and therefore is not considered an explosive.