Registration Dossier

Administrative data

Endpoint:
flash point
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Basic data given. Certificate of Analysis.

Data source

Reference
Reference Type:
other company data
Title:
Unnamed
Year:
2009

Materials and methods

Principles of method if other than guideline:
Cleveland open cup method.
GLP compliance:
no
Type of method:
open cup
Remarks:
ASTM D 92

Test material

Reference
Name:
Unnamed
Type:
Constituent
Details on test material:
- Analytical purity: > 95%
- Lot/batch No.: OE61122

Results and discussion

Flash point
Flash point:
250 °C

Any other information on results incl. tables

No value given for pressure, but assumed to be measured at normal pressure (1013 hPa) with open cup method.

Applicant's summary and conclusion