Endpoint:
partition coefficient
Type of information:
other: Expert statement
Adequacy of study:
supporting study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: The study has been performed according to OECD and EC guidelines and according to GLP principles.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2008
Report date:
2008

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
OECD Guideline 107 (Partition Coefficient (n-octanol / water), Shake Flask Method)
Deviations:
no
Qualifier:
according to guideline
Guideline:
EU Method A.8 (Partition Coefficient)
Deviations:
no
GLP compliance:
yes (incl. QA statement)

Test material

Constituent 1
Chemical structure
Reference substance name:
Lithium hexafluorophosphate(1-)
EC Number:
244-334-7
EC Name:
Lithium hexafluorophosphate(1-)
Cas Number:
21324-40-3
Molecular formula:
F6P.Li
IUPAC Name:
lithium(1+) hexafluoro-λ⁵-phosphanuide
Details on test material:
- Name of test material (as cited in study report): LiPF6
- Substance type: inorganic
- Physical state: white powder
- Analytical purity: > 99.9%
- Lot/batch No.: P07102202
- Expiration date of the lot/batch: 31 December 2008
- Stability under storage conditions: stable
- Storage condition of test material: At room temperature protected from light under nitrogen

Results and discussion

Any other information on results incl. tables

LiPF6 hydrolyses readily in contact with water. According to this it was not possible to determine the partition coefficient (n-octanol/water) of the test substance.

Applicant's summary and conclusion

Conclusions:
It was not possible to determine the partition coefficient (n-octanol/water) of the test substance.