Registration Dossier

Physical & Chemical properties

Melting point / freezing point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
melting point/freezing point
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
test procedure in accordance with national standard methods
Reason / purpose:
reference to same study
Qualifier:
equivalent or similar to
Guideline:
OECD Guideline 102 (Melting point / Melting Range)
GLP compliance:
yes
Type of method:
capillary method
Melting / freezing pt.:
356.15 K
Atm. press.:
101.3 kPa
Conclusions:
Melting Point = 83°C (356.15 K)
Executive summary:

The melting point was determined using a method based on OECD Method 102. Charged a glass capillary tube with 3-4 mm of test substance. Placed the tube in one of the Mel-Temp II receptacles. Set the apparatus power level to 3. Melting Point = 83°C (356.15 K)

Description of key information

Equivalent to OECD Guideline 102

Key value for chemical safety assessment

Melting / freezing point at 101 325 Pa:
356.15 K

Additional information

83°C