Registration Dossier

Administrative data

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: the study was conducted according to EEC Test Method A9 Flash Point with GLP compliance.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2010
Report Date:
2010

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
EU Method A.9 (Flash-Point)
GLP compliance:
yes (incl. certificate)
Type of method:
closed cup

Test material

Reference
Name:
Unnamed
Type:
Constituent
Type:
Constituent
Details on test material:
As per IUCLID5 Sections 1.1. - 1.4.

Results and discussion

Flash point
Flash point:
15.5 °C
Atm. press.:
1 023 mBar

Applicant's summary and conclusion

Conclusions:
The duplicate determined flash points of Crude 1,3-dichloropropene were 15°C and 16°C. Therefore the Flash Point of Crude 1,3-dichloropropene at 1023 mbar was 15.5 °C.
Executive summary:

The Flash Point of Crude 1,3 -dichloropropene was determined by EEC Test Method A9 by closed cup with GLP compliance. The duplicate determined flash points of Crude 1,3-dichloropropene were 15°C and 16°C. Therefore the Flash Point of Crude 1,3-dichloropropene at 1023 mbar was 15.5 °C.