Registration Dossier

Administrative data

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
4 January 2007
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Testing was performed according to guideline.

Data source

Reference
Reference Type:
other company data
Title:
Unnamed
Year:
2007
Report Date:
2007

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
Version / remarks:
2002
Deviations:
no
GLP compliance:
no
Remarks:
The company is ISO 9001/2000 certified which requires regular audits to demonstrate ability to provide products meeting customer & regulatory requirements including documentation of analytical procedures, maintenance & calibration of equipment
Type of method:
non-equilibrium method closed cup

Test material

Reference
Name:
Unnamed
Type:
Constituent

Results and discussion

Flash point
Flash point:
131 °C
Atm. press.:
760 mm Hg

Applicant's summary and conclusion

Conclusions:
The flash point of the test substance is 131 deg. C at 760 mmHg and would not be considered a flammable liquid according to GHS criteria.
Executive summary:

The flash point of the test material is 131 deg. C at 760 mmHg as determined by the Pensky-Martens Closed cup (PMCC) Tester according to ISO 2719:2002 guidelines. According to the GHS classification system, this substance does not meet the criteria for a flammable liquid.