Physical & Chemical properties

Auto flammability

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
auto-ignition temperature (liquids)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2010-10-22 to 2010-11-03
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.15 (Auto-Ignition Temperature (Liquids and Gases))
Version / remarks:
, 2008
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Remarks:
, signed 2010-08-25
Key result
Auto-ignition temperature:
235 °C
Atm. press.:
>= 1 003.1 - <= 1 004.5 hPa
Remarks on result:
other:

According to the tests, the auto-ignition temperature rounded down with an accuracy of 5 K was determined to be 235 °C.






















































































































2ndTest series



3rdTest series



Temperature



Droplets



Ignition



Temperature



Droplets



Ignition



239



10



+



240



10



+



235



10



-



240



9



-



235



8



-



236



10



-



235



6



-



236



8



-



235



4



-



235



6



-



235



2



-



235



4



-



235



9



-



235



2



-



235



7



-



235



1



-



235



5



-



235



9



-



235



3



-



235



7



-



235



1



-



235



5



-



235



10



-



235



3



-



Atmospheric pressure: 1003,1 hPa



Atmospheric pressure: 1004.5 hPa



 


The test item has an auto-ignition temperature of 235 °C according to the Regulation EC 440/2008 Method A.15. Auto-Ignition Temperature (Liquids and Gases).


It is note here that according to ECHA guidance –Guidance on information requirements and chemical safety assessment; chapter R.7A: Endpoint specific guidance, May 2008, the auto-ignition temperature for liquids are not used directly for classification and labeling according to regulation (EC) 1272/2008. However, they can be used in the chemical safety assessment in considering risks associated with processing the substance.


Nevertheless, according to DIN EN 13463-1 the test item has to be assigned to temperature class T3 (see the following Table).


Temperature classes


































Temperature class



Maximum surface temperature / minimum auto ignition temperature [°C]



T1



450



T2



300



T3



200



T4



135



T5



100



T6



85



 

Conclusions:
According to EU method A.15 (2008), the auto-ignition temperature rounded down with an accuracy of 5 K was determined to be 235 °C between 1003.1 hPa and 1004.5 hPa.

Description of key information

The auto-ignition temperature of the test item was determined at 235 °C at ca. 1004 hPa .

Key value for chemical safety assessment

Autoflammability / Self-ignition temperature at 101 325 Pa:
235 °C

Additional information