Registration Dossier

Administrative data

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Study performed according to international guideline but not GLP.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2008
Report Date:
2008

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
Version / remarks:
2002
GLP compliance:
no
Type of method:
closed cup

Test material

Reference
Name:
Unnamed
Type:
Constituent

Results and discussion

Flash point
Atm. press.:
1 018.9 hPa
Remarks on result:
other: No flash point

Applicant's summary and conclusion

Conclusions:
No flash point observed until 95 °C. After 95°C, the flamme goes out during immersion because of vapour pressure.