Registration Dossier

Physical & Chemical properties

Stability: thermal, sunlight, metals

Currently viewing:

Administrative data

Endpoint:
stability: thermal, sunlight, metals, other
Remarks:
Migrated from section 'Stability: thermal, sunlight, metals'
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: GLP guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2010
Report date:
2011

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
OECD Guideline 113 (Screening Test for Thermal Stability and Stability in Air)
GLP compliance:
yes

Test material

Constituent 1
Details on test material:
- Name of test material (as cited in study report): 1-Ethyl-3-methylimidazolium ethylsulfat
- Analytical purity: 98 %

Results and discussion

For thermal stability study

Test substance thermally stable:
no
Sublimation:
no
Transformation products:
not measured

Any other information on results incl. tables

1st reaction:

Onset temperature: 255 °C

Peak temperature: 295 °C

Energy release: 50 J/g

2nd reaction:

Onset temperature: 340 °C

Peak temperature: 354 °C

Energy release: 300 J/g

Applicant's summary and conclusion