Administrative data

Endpoint:
pH
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Justification for type of information:
Data is from experimental study report

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2018
Report date:
2018

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
OECD Guideline 122 (Determination of pH, Acidity and Alkalinity)
GLP compliance:
no

Test material

Constituent 1
Chemical structure
Reference substance name:
N-tert-butylacrylamide
EC Number:
203-505-6
EC Name:
N-tert-butylacrylamide
Cas Number:
107-58-4
Molecular formula:
C7H13NO
IUPAC Name:
N-tert-butylacrylamide
Test material form:
solid: crystalline
Details on test material:
- Name of test material: N-tert-Butylacrylamide
- Molecular formula: C7-H13-N-O
- Molecular weight: 127.1857g/mol
- Smiles notation: CC(C)(C)NC(=O)C=C
- InChl: 1S/C7H13NO/c1-5-6(9)8-7(2,3)4/h5H,1H2,2-4H3,(H,8,9)
- Substance type: organic
- Physical state: solid

Results and discussion

pH value
Key result
pH value:
6.52
Temp.:
26.2 °C
Remarks on result:
other: Weakly acidic in nature

Any other information on results incl. tables

 Method Details      Observations
Guideline   OECD 122  
  Method  Digital pH meter  
 Principle of Method  The mean pH of an aqueous solution or dispersion in water was determined with a pH measurement interface equipped with an appropriate electrode system.  
 Temperature of 1% w/v test dispersion mean    26.2°C
 pH (RESULT)    6.52
 Inference

1. Acidic

2. Basic

3. Neutral

 weakly acidic

Applicant's summary and conclusion

Conclusions:
The pH determination of test chemical was done as per the test guideline OECD 122. The mean pH of the test dispersion was determined with the help of digital pH meter. The mean pH was determined to be 6.52 at 26.2 °C.
Executive summary:

The pH determination of test chemical was done as per the test guideline OECD 122. The mean pH of the test dispersion was determined with the help of digital pH meter. The mean pH was determined to be 6.52 at 26.2 °C.