Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
08 November 2014 to 27 November 2014
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
equilibrium method closed cup
Flash point apparatus:
Setaflash apparatus
Key result
Flash point:
> 300 °C
Remarks on result:
no flash point according to standard method

RESULTS

- In the preliminary assessment, the test item burnt with a yellow flame and black smoke.

- Results of the flash point determination are shown in Table 3.1 (below).

 

TABLE 3.1 – RESULTS OF FLASH POINT DETERMINATION

Test temperature (°C)

Observations

17.0 (fresh sample) to 67.0

No flash

67.0 (fresh sample) to 97.0

No flash

102.0 (fresh sample) to 152.0

No flash

152.0 (fresh sample) to 202.0

No flash

202.0 (fresh sample) to 252.0

No flash

252.0 (fresh sample)

No flash

257.0

No flash

262.0

A blue flame/yellow flame spread across the sample cup

262.0 (fresh sample)

No flash

267.0

No flash

272.0

No flash

277.0

No flash but flame increased in size when dipped

282.0

No flash but flame increased in size when dipped

287.0

No flash but flame increased in size when dipped

292.0

No flash but flame increased in size when dipped

297.0

No flash but flame increased in size when dipped

300.0

No flash but flame increased in size when dipped

300.0 (fresh sample)

No flash but flame increased in size when dipped

Atmospheric pressure: Not reported

Corrected flash point: No definitive flash point determined below 300 °C

Interpretation of results:
GHS criteria not met
Conclusions:
The test item was determined not to have a flash point below 300 °C.
Executive summary:

GUIDELINE

The determination was carried out using a closed cup Setaflash 30000-0 flash point tester and was designed to be compatible with Method A.9 Flash Point of Commission Regulation (EC) No 440/2008 of 30 May 2008.

 

RESULTS

The test item was determined not to have a flash point below 300 °C.

Description of key information

The test item was determined not to have a flash point below 300 °C (EU Method A.9).

Key value for chemical safety assessment

Additional information

GUIDELINE

The determination was carried out using a closed cup Setaflash 30000-0 flash point tester and was designed to be compatible with Method A.9 Flash Point of Commission Regulation (EC) No 440/2008 of 30 May 2008.

 

RESULTS

The test item was determined not to have a flash point below 300 °C.