Registration Dossier

Diss Factsheets

Toxicological information

Eye irritation

Currently viewing:

Administrative data

Endpoint:
eye irritation: in vivo
Type of information:
migrated information: read-across based on grouping of substances (category approach)
Adequacy of study:
weight of evidence
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Guideline study with acceptable restrictions.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
1988
Report date:
1988

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
OECD Guideline 405 (Acute Eye Irritation / Corrosion)
Deviations:
no
GLP compliance:
no

Test material

Constituent 1
Reference substance name:
Alcohols, C12-14, ethoxylated
EC Number:
500-213-3
EC Name:
Alcohols, C12-14, ethoxylated
Cas Number:
68439-50-9
IUPAC Name:
68439-50-9
Details on test material:
- Name of test material (as cited in study report): fatty alcohol-(C12-C14) polyethylene glycolether
- Ethoxylation degree: 2
- Analytical purity: ca. 100%
- Lot/batch No.: 12

Test animals / tissue source

Species:
rabbit
Strain:
other: Kleine weiße Russen

Test system

Vehicle:
unchanged (no vehicle)
Controls:
not required
Amount / concentration applied:
0.1 mL
Duration of treatment / exposure:
n.a.
Observation period (in vivo):
6 days
Number of animals or in vitro replicates:
3

Results and discussion

In vivo

Resultsopen allclose all
Irritation parameter:
cornea opacity score
Basis:
mean
Time point:
other: 24+48+72 h
Score:
0
Max. score:
4
Irritation parameter:
iris score
Basis:
mean
Time point:
other: 24+48+72 h
Score:
0
Max. score:
2
Irritation parameter:
conjunctivae score
Basis:
mean
Time point:
other: 24+48+72 h
Score:
0.3
Max. score:
3
Reversibility:
fully reversible
Irritation parameter:
chemosis score
Basis:
mean
Time point:
other: 24+48+72 h
Score:
0
Max. score:
4

Applicant's summary and conclusion

Interpretation of results:
not irritating
Remarks:
Migrated information Criteria used for interpretation of results: EU