Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 233-713-2 | CAS number: 10326-41-7
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Eye irritation
Administrative data
- Endpoint:
- eye irritation: in vitro / ex vivo
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- 1996-01-18 to 1996-03-12
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- comparable to guideline study
Data source
Reference
- Reference Type:
- study report
- Title:
- Unnamed
- Year:
- 1 996
- Report date:
- 1996
Materials and methods
Test guideline
- Qualifier:
- equivalent or similar to guideline
- Guideline:
- OECD Guideline 438 (Isolated Chicken Eye Test Method for Identifying Ocular Corrosives and Severe Irritants)
- Version / remarks:
- Study performed prior to validation and publication of the test guideline.
- Deviations:
- yes
- Remarks:
- No positive controls
- GLP compliance:
- yes
Test material
- Reference substance name:
- L-(+)-lactic acid
- EC Number:
- 201-196-2
- EC Name:
- L-(+)-lactic acid
- Cas Number:
- 79-33-4
- Molecular formula:
- C3H6O3
- IUPAC Name:
- (2S)-2-hydroxypropanoic acid
Constituent 1
Test animals / tissue source
- Species:
- other: Chicken Enucleated Eye Test
Test system
- Vehicle:
- unchanged (no vehicle)
- Amount / concentration applied:
- Concentration: 100 %
Amount applied: 0.03 mL - Duration of treatment / exposure:
- 10 seconds
- Number of animals or in vitro replicates:
- 3
- Details on study design:
- Approximately 7 weeks old, male or female chickens (ROSS, spring chickens), body weight range approximately 2.5-3.0 kg, were used as eye-donors. Heads of these animals were obtained from poultry slaughterhouse v.d. Bor, Amersfoortseweg 118, Nijkerkerveen, the Netherlands. Heads of the animals were cut off immediately after sedation of the animals by electric shock and incision of the neck for bleeding, and before they reached the next station on the process line. The heads were placed in small plastic boxes (3 heads per box) on a bedding of paper tissues moistened with isotonic saline. Next, they were transported to the testing facility. During transportation, the heads were kept at ambient temperature. Within 2 hours after kill, eyes were carefully dissected and placed in a superfusion apparatus using the following procedure: First the eye-lids were carefully removed without damaging the cornea and a small drop of Fluorescein sodium BP 2% w/v (Minims, Smith & Nephew Ltd., Romford, England) was applied to the corneal surface for a few seconds and subsequently rinsed off with isotonic saline of ambient temperature. Next, the head with the fluorescein-treated cornea was examined with a slit-lamp microscope (Slit-lamp 900 CN, Haag-Streit AG, Liebefeld-Bern, Switzerland), to ensure that the cornea was not damaged. If undamaged, the eye was further dissected from the head without damaging the eye or cornea. Care was taken to remove the eye-ball from the orbit without cutting off the optical nerve too short. The enucleated eye was placed in a stainless steel clamp with the cornea positioned vertically and transferred to a chamber of the superfusion apparatus (TNO, Zeist, the Netherlands). The clamp holding the eye was positioned in such a way that the entire cornea was supplied with isotonic saline from a bent, stainless steel tube, at a rate of ca 0.10-0.15 mL/min (peristaltic pump, Desaga STA 131900, Heidelberg, Germany). The chambers of the superfusion apparatus as well as the saline were temperature controlled at 32 ± 1.5 °C (waterpump, Thermomix 1441, B. Braun Melsungen AG, Melsungen, Germany). After placing in the superfusion apparatus, the eyes were examined again with the slit-lamp microscope to ensure that they were not damaged. Corneal thickness was measured using the Depth Measuring Attachment no. II for the Haag-Streit slit-lamp microscope. Thickness of the cornea was expressed in instrument units. An accurate measurement was taken at the corneal apex of each eye. Eyes with a corneal thickness deviating more than 10% of the average corneal thickness of the eyes, or eyes that were unacceptably stained with fluorescein (score higher than 0.5), indicating the cornea to be permeable, or eyes that showed any other signs of damage, were rejected as test eyes and replaced, if necessary. Per test sample, three eyes were selected for testing, whereas one additional eye was rinsed with isotonic saline only and served as a control of the experimental conditions. After an equilibration period of 45-60 minutes, the corneal thickness of the eyes were measured again to determine the zero reference value for corneal swelling calculations. At time t = 0, i.e. immediately after the zero reference measurement, each of the three test samples was applied to the designated test eyes. The following procedure applied for each test eye:
The clamp holding the eye was placed on paper tissues outside the chamber with the cornea facing upwards. Each of the two liquid samples was applied in an amount of 0.03 mL from a micropipette (Nichiryo Co., Ltd., model 8100, Tokyo, Japan), in such a way that the entire surface of the cornea was bathed with the test material. With the solid sample, the cornea was powdered with 0.03 g of the test material. After a total exposure period of 10 seconds, the corneal surface was rinsed thoroughly with 20 mL of isotonic saline of ambient temperature. After rinsing, each eye in the holder was returned to its chamber.
The control eye and test eyes were examined at 0, 30, 75, 120, 180 and 240 minutes after treatment, using the criteria and scoring system, given in the annex. Fluorescein retention was only scored at 30 minutes after treatment. All examinations were carried out with the slit-lamp microscope.
Results and discussion
In vitro
Resultsopen allclose all
- Irritation parameter:
- cornea opacity score
- Remarks:
- after 240 min
- Run / experiment:
- 1
- Value:
- ca. 4
- Vehicle controls validity:
- valid
- Negative controls validity:
- valid
- Positive controls validity:
- not examined
- Remarks on result:
- positive indication of irritation
- Irritation parameter:
- cornea opacity score
- Remarks:
- after 240 min
- Run / experiment:
- 2
- Value:
- ca. 4
- Vehicle controls validity:
- valid
- Negative controls validity:
- valid
- Positive controls validity:
- not examined
- Remarks on result:
- positive indication of irritation
- Irritation parameter:
- cornea opacity score
- Remarks:
- after 240 min
- Run / experiment:
- 3
- Value:
- ca. 4
- Vehicle controls validity:
- valid
- Negative controls validity:
- valid
- Positive controls validity:
- not examined
- Remarks on result:
- positive indication of irritation
- Irritation parameter:
- percent corneal swelling
- Remarks:
- after 240 min
- Run / experiment:
- 1
- Value:
- ca. 31
- Vehicle controls validity:
- valid
- Negative controls validity:
- valid
- Positive controls validity:
- not examined
- Remarks on result:
- positive indication of irritation
- Irritation parameter:
- percent corneal swelling
- Remarks:
- after 240 min
- Run / experiment:
- 2
- Value:
- ca. 26
- Vehicle controls validity:
- valid
- Negative controls validity:
- valid
- Positive controls validity:
- not examined
- Remarks on result:
- positive indication of irritation
- Irritation parameter:
- percent corneal swelling
- Remarks:
- after 240 min
- Run / experiment:
- 3
- Value:
- ca. 28
- Vehicle controls validity:
- valid
- Negative controls validity:
- valid
- Positive controls validity:
- not examined
- Remarks on result:
- positive indication of irritation
- Irritation parameter:
- fluorescein retention score
- Remarks:
- after 30 min
- Run / experiment:
- 1
- Value:
- ca. 3
- Vehicle controls validity:
- valid
- Negative controls validity:
- valid
- Positive controls validity:
- not examined
- Remarks on result:
- not determinable
- Irritation parameter:
- fluorescein retention score
- Remarks:
- after 30 min
- Run / experiment:
- 2
- Value:
- ca. 3
- Vehicle controls validity:
- valid
- Negative controls validity:
- valid
- Positive controls validity:
- not examined
- Remarks on result:
- positive indication of irritation
- Irritation parameter:
- fluorescein retention score
- Remarks:
- after 30 min
- Run / experiment:
- 3
- Value:
- ca. 3
- Vehicle controls validity:
- valid
- Negative controls validity:
- valid
- Positive controls validity:
- not examined
- Remarks on result:
- positive indication of irritation
Applicant's summary and conclusion
- Interpretation of results:
- Category 1 (irreversible effects on the eye) based on GHS criteria
- Conclusions:
- In conclusion, based on the given conditions the test item is considered severely irritating to eyes.
- Executive summary:
Lactic acid 88% (sample code HS88), was examined undiluted for eye irritating/corrosive potential in an ex vivo bioassay, namely the Enucleated Eye Test with chicken eyes (CEET). The eyes were collected as waste material from a slaughterhouse for chickens, which were killed for human consumption. HS88 induced severe corneal effects. On the basis of the results obtained with this in vitro (ex vivo) assay, HS88 can be considered severely irritating to eyes.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.