Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Followed acceptable guideline and GLP requirements
Qualifier:
equivalent or similar to guideline
Guideline:
EU Method A.9 (Flash-Point)
Qualifier:
according to guideline
Guideline:
ISO 3679 (Determination of flash point - Rapid equilibrium closed cup method)
Version / remarks:
2004
Qualifier:
according to guideline
Guideline:
ISO No., other: ASTM D-3728-89
GLP compliance:
yes (incl. QA statement)
Type of method:
equilibrium method closed cup
Flash point:
> 145 - < 147 °C
Atm. press.:
101.325 kPa
Remarks on result:
other: The flash point temperature was corrected to a pressure of 101.325 kPa using the equation FP = C +0.23 (101.325 -B) where FP was the corrected flash point, C was the observed flash point, and B was the ambient atmospheric pressure in kPa

Temperature with positive observations in flash point test (closed cup) 

Temperature (degrees C)

Observation

149.0 (fresh sample)

Blue flash spread across cup

146.0

Blue flash spread across cup

146.0 (fresh sample)

Blue flash spread across cup

147.0

Blue flash spread across cup

147.0 (fresh sample)

Blue flash spread across cup

147.0 (fresh sample)

Blue flash spread across cup

Atmospheric pressure

103.09 kPa

Corrected flash point

146.594 degrees C

Flash point determined to be 147 +/- 2 degrees C

Conclusions:
The flash point was determined by using a closed cup equilibrium method, using a procedure designed to be compatible with Method A9 “Flash Point” of Commission (EC) No. 440/2008 of 30 May 2008. The flash point of the test item was determined to be 147 +/- 2 degrees C.
Executive summary:

The flash point was determined by using a closed cup equilibrium method, using a procedure designed to be compatible with Method A9 “Flash Point” of Commission (EC) No. 440/2008 of 30 May 2008. The flash point of the test item was determined to be 147 +/- 2 degrees C. 

Description of key information

The flash point was determined by using a closed cup equilibrium method, using a procedure designed to be compatible with Method A9 “Flash Point” of Commission (EC) No. 440/2008 of 30 May 2008. The flash point of the test item was determined to be 147 +/- 2 degrees C. 

Key value for chemical safety assessment

Flash point at 101 325 Pa:
147 °C

Additional information