Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 939-455-3 | CAS number: 1469983-49-0
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Partition coefficient
Administrative data
Link to relevant study record(s)
- Endpoint:
- partition coefficient
- Type of information:
- experimental study
- Adequacy of study:
- disregarded due to major methodological deficiencies
- Study period:
- From 25 August 2006 to 26 September 2006
- Reliability:
- 3 (not reliable)
- Rationale for reliability incl. deficiencies:
- other: see 'Remark'
- Remarks:
- The study is considered as not reliable based on the following parameters: - No characterization of the test item - Determination of the partition coefficient with the HPLC method for a surface active agent without adjustment of the mobile phase pH's - Some compounds were eluted before the dead time of the column -The deviation between the values of log Pow derived from two measurements made under identical conditions and using the same set of reference substances is higher than 0.1 log units - No detailed information on the analytical method used (type of HPLC column, wavelenght of the detector...) - The study was not performed according to the last Guideline available at the time of the test
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 117 (Partition Coefficient (n-octanol / water), HPLC Method)
- Deviations:
- yes
- Remarks:
- The deviation between the values of log Pow derived from two measurements made under identical conditions and using the same set of reference substances is higher than 0.1 log units.
- GLP compliance:
- not specified
- Type of method:
- HPLC method
- Partition coefficient type:
- octanol-water
- Analytical method:
- high-performance liquid chromatography
- Type:
- log Pow
- Partition coefficient:
- 1.38
- Remarks on result:
- other: weighted average value
- Conclusions:
- The weighted average value of Log Pow for the test item is 1.38.
- Executive summary:
The study was assessed for the determination of the partition coefficient of the test item with HPLC method based on that outlined OECD guideline 117. A deviation from the guideline was observed during the study. Indeed, the deviation between the values of log Pow derived from two measurements made under identical conditions and using the same set of reference substances is higher than 0.1 log units. So the study didn't meet the quality criteria described in the OECD guideline 117. Under the conditions employed (HPLC conditions), one peak was detected using the Diode Array Detector. The Refractive Index Detector recorded two peaks with log Pow values of <0 and 2.03. The weighted average log Pow for this sample gave a figure of 1.38 (RI).
- Endpoint:
- partition coefficient
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- From 4 October 2012 to 25 January 2013
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- guideline study
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 123 (Partition Coefficient (1-Octanol / Water), Slow-Stirring Method)
- Deviations:
- no
- GLP compliance:
- yes (incl. QA statement)
- Remarks:
- 2012-12-15
- Type of method:
- slow-stirring method
- Partition coefficient type:
- octanol-water
- Analytical method:
- high-performance liquid chromatography
- Key result
- Type:
- log Pow
- Partition coefficient:
- 2.1
- Temp.:
- 25 °C
- pH:
- >= 7.6 - <= 7.85
- Remarks on result:
- other: log Pow of the C12 fraction (weighted average value)
- Conclusions:
- Using the low stirring method, it was shown that the weighed average value of the 1-octanol/water partition coefficient log10 Pow of the C12 fraction present in test item is equal to 2.10 ± 0.02 at 25 ± 1°C.
- Executive summary:
The n-octanol/water partition coefficient of the test item (= substance EC 939-455-3) was investigated in a GLP-compliant study performed in accordance with OECD Guideline 123 (Partition Coefficient (1-Octanol / Water), Slow-Stirring Method). The mean n-octanol/water partition coefficient log10 Pow of the C12 fraction present in test item was 2.10 ± 0.02 at 25°C.
Referenceopen allclose all
The table above presented the HPLC retention times and log Pow data for reference compounds used in the study. Compounds were injected into the mobile phase of 50:50 methanol:water
Reference Compound |
Detector |
Mean Retention time (min) |
Calculated log Pow |
Thiourea |
DAD |
2.121 |
- |
RI |
2.679 |
- |
|
2-butanone |
DAD |
3.109 |
0.35 |
RI |
3.667 |
0.35 |
|
Aniline |
DAD |
3.846 |
0.82 |
RI |
4.404 |
0.82 |
|
Benzonitrile |
DAD |
6.261 |
1.56 |
RI |
6.820 |
1.56 |
|
p-cresol |
DAD |
7.405 |
1.76 |
RI |
7.961 |
1.90 |
|
Methylbenzoate |
DAD |
13.190 |
2.38 |
RI |
13.744 |
2.38 |
|
1-napthol |
DAD |
16.842 |
2.62 |
RI |
17.392 |
2.62 |
The calibration graph of log(retention time) against published log Pow values for reference standards were presented in Attachment 1.
The test item appeared to fully dissolve in the mobile phase of 50:50 methanol: water used in this study.
The Diode Array Detector (DAD) showed a single peak forming before t0, implying a low Log Pow value.
The refractive Index Detector (RI) presented a large peak also before t0, implying a low Log Pow value for this sample. However, a second smaller peak was also on noted on the RI detector with a retention time of approximately 9.9 minutes. In the opinion of the Principle Investigator, this peak may well be an artefact form the production process of the test item. The weighted average of the two peaks was therefore 1.38 in this study. The data obtained with the sample were presented in the table above:
Detector |
Peak number |
Mean Retention time (min) |
log Pow |
% Area under peak |
DAD |
1 |
1.842 |
<0 |
- |
RI |
1 |
2.4596 |
<0 |
77.8 |
RI |
2 |
9.953 |
2.03 |
22.2 |
Results:
Calibration curve for 1 -octanol phases analysis
Reference of calibration solution | Peak area (area units) | Conc (mg/L) | Response factor | Final Volume (ml) | Dilution factor | Sample weight (mg) | Conc back-calc | Diff |
A | C= (w*P)/(V*Df) | RF = A/C | V | Df | w | C'= (A-b)/a | % | |
Lin 25% | 1830264 | 19.31 | 9.48048E+04 | 100 | 4.0 | 20.11 | 18.49 | -4.25% |
Lin 25% | 1845749 | 19.31 | 9.56069E+04 | 100 | 4.0 | 20.11 | 18.65 | -3.37% |
Lin 50% | 3905839 | 39.71 | 9.83700E+04 | 100 | 1.0 | 10.34 | 40.46 | 1.89% |
Lin 50% | 3915468 | 39.71 | 9.86125E+04 | 100 | 1.0 | 10.34 | 40.56 | 2.14% |
Lin 75% | 5574447 | 57.14 | 9.75591E+04 | 100 | 1.0 | 14.88 | 58.12 | 1.72% |
Lin 75% | 5493480 | 57.14 | 9.61421E+04 | 100 | 1.0 | 14.88 | 57.26 | 0.21% |
REF05 | 7463735 | 78.84 | 9.46752E+04 | 100 | 1.0 | 20.53 | 78.11 | -0.91% |
REF05 | 7502554 | 78.84 | 9.51676E+04 | 100 | 1.0 | 20.53 | 78.52 | -0.39% |
Lin 125% | 9176261 | 96.38 | 9.52052E+04 | 100 | 1.0 | 25.10 | 96.24 | -0.16% |
Lin 125% | 9169449 | 96.38 | 9.51346E+04 | 100 | 1.0 | 25.10 | 96.16 | -0.23% |
Lin 150% | 10797715 | 112.59 | 9.59040E+04 | 100 | 1.0 | 29.32 | 113.40 | 0.72% |
Lin 150% | 10661311 | 112.59 | 9.46925E+04 | 100 | 1.0 | 29.32 | 111.95 | -0.57% |
Response function Peak Area = 94488.13*Concentration + 83143.53
The graph of the calibration curve is shown in Attachment 1.
Calibration curve for water phase analysis:
Reference of calibration solution | Peak area (area units) | Conc (mg/L) | Response factor | Final Volume (ml) | Dilution factor | Sample weight (mg) | Conc back-calc | Diff |
A | C= (w*P)/(V*Df) | RF = A/C | V | Df | w | C'= (A-b)/a | % | |
REF 05 dil20 | 369203 | 3.94 | 9.36645E+04 | 100 | 20 | 20.53 | 3.90 | -1.01% |
REF 05 dil20 | 351222 | 3.94 | 8.91028E+04 | 100 | 20 | 20.53 | 3.69 | -6.34% |
REF 05 dil10 | 699817 | 7.88 | 8.87696E+04 | 100 | 10 | 20.53 | 7.74 | -1.78% |
REF 05 dil10 | 710573 | 7.88 | 9.01340E+04 | 100 | 10 | 20.53 | 7.86 | -0.25% |
REF 05 dil5 | 1413337 | 15.77 | 8.96387E+04 | 100 | 5 | 20.53 | 16.03 | 1.65% |
REF 05 dil5 | 1437975 | 15.77 | 9.12013E+04 | 100 | 5 | 20.53 | 16.32 | 3.49% |
REF 05 dil4 | 1720595 | 19.71 | 8.73009E+04 | 100 | 4 | 20.53 | 19.60 | -0.56% |
REF 05 dil4 | 1733152 | 19.71 | 8.79380E+04 | 100 | 4 | 20.53 | 19.75 | 0.20% |
REF 05 dil2,5 | 2735643 | 31.53 | 8.67520E+04 | 100 | 2.5 | 20.53 | 31.40 | -0.44% |
REF 05 dil2,5 | 2734947 | 31.53 | 8.67299E+04 | 100 | 2.5 | 20.53 | 31.39 | -0.48% |
Response function Peak Area = 86061.61*Concentration + 33709.60
The graph of the calibration curve is shown in Attachment 1.
Main test results:
The three filtered aliquots of 50 mL obtained from the 1-octanol saturated phase were analyzed and the concentrations of the C12 fraction were found to be equal to 1.86 g/L (4.84 g/L of test item). This value is lower than the theoretical one and shows a weak dissolution of test item during the two hours of preparation.
The results for the C12 fraction concentration in the two phases at each time are given in the following table:
Vessel number and sampling time | Concentration in the aqueous phase (mg/l) | Concentration in the 1-octanol phase (mg/l) | Pow ratio | log Pow |
12-091 Z1T=93H | 12.70 | 1499 | 118.00 | 2.07 |
12-091 Z2T=93H | 11.44 | 1524 | 133.20 | 2.12 |
12-091 Z3T=93H | 12.14 | 1558 | 128.30 | 2.11 |
12-091 Z1T=117H | 11.24 | 1497 | 133.20 | 2.12 |
12-091 Z2T=117H | 11.94 | 1539 | 128.90 | 2.11 |
12-091 Z3T=117H | 11.78 | 1582 | 134.30 | 2.13 |
12-091 Z1T=137H | 11.54 | 1503 | 130.20 | 2.11 |
12-091 Z2T=137H | 12.18 | 1601 | 131.40 | 2.12 |
12-091 Z3T=137H | 13.38 | 1629 | 121.70 | 2.09 |
12-091 Z1T=144H | 11.48 | 1511 | 131.60 | 2.12 |
12-091 Z2T=144H | 12.78 | 1513 | 118.40 | 2.07 |
12-091 Z3T=144H | 13.26 | 1569 | 118.30 | 2.07 |
12-091 Z1T=163H | 12.02 | 1489 | 123.90 | 2.09 |
12-091 Z2T=163H | 12.14 | 1552 | 127.80 | 2.11 |
12-091 Z3T=163H | 12.34 | 1599 | 129.60 | 2.11 |
The pH of the saturated water phase at the start of the test was 7.88 at 21 °C.The measured pH of the aqueous phases were between 7.60 and 7.85 at 21 °C.
The average value of log Pow of the different vessel units is calculated as the average of the results of the individual experimental units weighed with their respective variances.The results are shown in the following table.
Vessel Z1 | Mean value Z1 | Standard deviation Z1 | Vessel Z2 | Mean value Z2 | Standard deviation Z2 | Vessel Z3 | Mean value Z3 | Standard deviation Z3 |
2,07 | 2,102 | 0,02 | 2,12 | 2,106 | 0,02 | 2,11 | 2,102 | 0,02 |
2,12 | 2,11 | 2,13 | ||||||
2,11 | 2,12 | 2,09 | ||||||
2,12 | 2,07 | 2,07 | ||||||
2,09 | 2,11 | 2,11 |
Mean / Vessel | Average | Standard deviation | |
Vessel Z1 | 2,102 | 2,103 | 0,02 |
Vessel Z2 | 2,106 | ||
Vessel Z3 | 2,102 |
Using the low stirring method, it was shown that the weighed average value of the 1-octanol/water partition coefficient log10 Pow of the C12 fraction present in test item is equal to 2.10 ± 0.02 at 25 ± .1°C.
Demonstration of attainment of equilibrium:
Achievement of chemical equilibrium is demonstrated by plotting for each vessel unit log Pow against time as shown in the figures shown in Attachment 2 where the slopes are very near to 0.
Description of key information
The n-octanol/water partition coefficient of the substance 1-Propanaminium, N-(3-aminopropyl)-2-hydroxy-N,N-dimethyl-3-sulfo-, N-(C8-18(even numbered) acyl) derivs., hydroxides, inner salts (EC 939-455-3) was investigated in a GLP-compliant study (Meriaux, 2013) performed in accordance with OECD Guideline 123 (Partition Coefficient (1-Octanol / Water), Slow-Stirring Method). The mean n-octanol/water partition coefficient log10 Pow of the C12 fraction present in the the substance was 2.10 ± 0.02 at 25°C.
The n-octanol/water partition coefficient of the substance had been previously investigated in a study (Hill, 2006) performed in accordance with OECD Guideline 117 (Partition Coefficient (n-octanol / water), HPLC Method). The result of that study was not considered in the assesment as the HPLC method is not suitable for surface-active substance (the substance proved to be a surfactant) and the study suffered from various methodological deficiencies.
Key value for chemical safety assessment
- Log Kow (Log Pow):
- 2.1
- at the temperature of:
- 25 °C
Additional information
The n-octanol/water partition coefficient of the substance 1-Propanaminium, N-(3-aminopropyl)-2-hydroxy-N,N-dimethyl-3-sulfo-, N-(C8-18(even numbered) acyl) derivs., hydroxides, inner salts (EC 939-455-3) was investigated in a GLP-compliant study (Meriaux, 2013) performed in accordance with standard methods, without deviations. The study is considered as reliable (Klimisch 1) and was selected as key study for the endpoint. The n-octanol/water partition coefficient of the substance was investigated in another study (Hill, 2006) which is considered as not reliable (Klimisch 3) and was disregarded for the endpoint.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.