Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
test procedure in accordance with national standard methods with acceptable restrictions
Qualifier:
according to guideline
Guideline:
other: DIN 51584
GLP compliance:
no
Type of method:
open cup
Flash point:
210 °C
Atm. press.:
ca. 1 013 hPa
Remarks on result:
other: Pressure not reported. Ambient conditions (ca. 1013 hPa) can be assumed as the test was conducted using an open cup system.

Description of key information

210 °C at ca. 1013 hPa (DIN 51584, open cup)

Key value for chemical safety assessment

Flash point at 101 325 Pa:
210 °C

Additional information

The flash point of the test substance was determined using an open cup method according to DIN 51584. Since the measured flash point is far above the classification limit and above 200 °C, the open-cup method is accepted.