Registration Dossier

Physical & Chemical properties

Viscosity

Currently viewing:

Administrative data

Link to relevant study record(s)

Description of key information

The kinematic viscosity of the test item was determined according to OECD Guideline No. 114 with a capillary viscometer (Ubbelohde).

Key value for chemical safety assessment

Additional information

The viscosity of the test itemis:

  Kinematic viscosity: 1964 ± 8 mm2/s at 20 °C
                                426 ± 2 mm2/s at 40 °C

  Dynamic viscosity: 1706 ± 7 mPa.s at 20 °C
                              364 ± 2 mPa.s at 40 °C