Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2006-09-27 to 2007-04-18
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: GLP study performed according to OECD Guideline 104 (Vapour Pressure Curve) and (EU Method A.4 (Vapour Pressure) without deviations.
Cross-reference
Reason / purpose for cross-reference:
reference to other study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2007
Report date:
2007

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
OECD Guideline 104 (Vapour Pressure Curve)
Deviations:
no
Remarks:
The testing facility indicated that the protocol was followed without deviation.
Qualifier:
according to guideline
Guideline:
EU Method A.4 (Vapour Pressure)
Deviations:
no
Remarks:
The testing facility indicated that the protocol was followed without deviation.
Principles of method if other than guideline:
Not applicable
GLP compliance:
yes (incl. QA statement)
Remarks:
Department of Health of the Government of the United Kingdom
Type of method:
effusion method: vapour pressure balance

Test material

Reference
Name:
Unnamed
Type:
Constituent
Details on test material:
- Name of test material (as cited in study report): VRT-126028
- Molecular formula (if other than submission substance): not applicable
- Molecular weight (if other than submission substance): not applicable
- Smiles notation (if other than submission substance): not applicable
- InChl (if other than submission substance): not applicable
- Structural formula attached as image file (if other than submission substance): not applicable
- Substance type: no data
- Physical state: white powder
- Analytical purity: 99.3 area% by Gas Chromatography (GC)
- Impurities: no data
- Composition of test material, percentage of components: no data
- Isomers composition: no data
- Purity test date: 2006-05-22
- Lot/batch No.: 25414
- Expiration date of the lot/batch: May 2008
- Stability under test conditions: no data
- Storage condition of test material: at room temperature
- Other: no data

Results and discussion

Vapour pressure
Temp.:
25 °C
Vapour pressure:
0 Pa
Remarks on result:
other: The vapour pressure of 0.00002 Pa at 25 deg C was determined by extrapolation from the measurements between 51 and 96.0 deg C and is the mean result of two runs.

Applicant's summary and conclusion

Conclusions:
The vapour pressure of the test substance was found to be 0.00002 Pa at 25 deg C.
Executive summary:

Not applicable